Installation Manual
TypeDR Family with Class IISeriesDR-15, DR-30, DR-60, DR-100
DR-15-5 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 5V 2.4A
DR-15-12 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 12V 1.25A
DR-15-15 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 15V 1A
DR-15-24 INPUT: 100 -240VAC 0.88A 50/60Hz OUTPUT: 24V 0.63A
DR-30-5 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 5V 3A
DR-30-12 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 12V 2A
DR-30-15 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 15V 2A
DR-30-24 INPUT: 100 -240VAC 1.1A 50/60Hz OUTPUT: 24V 1.5A
DR-60-5 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 5V 6.5A
DR-60-12 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 12V 4.5A
DR-60-15 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 15V 4A
DR-60-24 INPUT: 100 -240VAC 1.8A 50/60Hz OUTPUT: 24V 2.5A
DR-100-12 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 12V 7.5A
DR-100-15 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 15V 6.5A
DR-100-24 INPUT: 100 -240VAC 3A 50/60Hz OUTPUT: 24V 4.2A
Introduction
DR with class II is a double insulated DIN rail power supply series, meaning it is ungrounded. Like other Mean Wells
DIN series, they can be mounted on a TS35 Standard DIN rail.
Installation
1Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
2The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top for DR-15, the input terminals on the right and output on the left for DR-30, DR-60, and DR-100.
Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
3Use stranded copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
6A
6-10A
13-16A
16-25A
Cross-section of
Lead(mm
2
)
0.75
1.00
1.5
2.5
NoteCurrent each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
1 DR15-100_1680-21407-0590-E-0418
Question and Answer IconNeed help?

Do you have a question about the Mean Well DR-15-12 and is the answer not in the manual?

Summary

Product Series and Introduction

DR Family Product Specifications

Lists DR series models with input/output specifications for DR-15, DR-30, DR-60, and DR-100.

Product Series Introduction

Explains the DR series as ungrounded, double insulated DIN rail power supplies mountable on TS35 rails.

Installation Guidelines and Wiring

Ventilation and Clearance Requirements

Specifies required ventilation clearances around the unit to prevent overheating and manage heat from adjacent devices.

Mounting Orientation Details

Details correct mounting orientations (vertical) and disallowed positions for optimal cooling.

Wire Selection and Connection Standards

Recommends stranded copper wire and details wire gauge based on current rating and derating notes.

Wire Temperature and Length Specifications

Specifies required wire temperature rating (UL1007) and recommended wire strapping length for terminals.

Terminal Torque and Screwdriver Recommendations

Specifies the recommended torque setting for terminal screws and the appropriate screwdriver type (3mm slotted).

Fuse and Circuit Breaker Compatibility

Lists recommended fuses and maximum PSU connections per circuit breaker rating for 230V operation.

DIN Rail Mounting Instructions

Provides step-by-step instructions and diagrams for mounting the unit securely on a TS35 DIN rail.

Safety Warnings and Precautions

Electrical Shock and Burn Hazard Warnings

Warns of electrical shock, arc risk, and burn hazards; advises professional examination and avoiding contact after operation.

Fire and Short Circuit Prevention

Advises protecting unit openings from foreign objects and liquids to prevent fire and short circuits.

Installation Environment and Operating Limits

Specifies installation in pollution degree 2 environments and adherence to maximum operating temperatures and output ratings.

Fuse Replacement and System Disconnection

Instructs on disconnecting system voltage before maintenance and replacing fuses only with identical types for fire protection.

Mean Well DR-15-12 Specifications

General IconGeneral
BrandMean Well
ModelDR-15-12
CategoryPower Supply
LanguageEnglish

Related product manuals