Storage of Colloidal Silver
The finished silver solution is usable for months but it is losing effect continuously. Colloidal silver
with a large amount of positively charged ions is particularly effective and should be used as fresh
as possible. In order to keep its optimal condition, the following advices have to be taken into
consideration:
Do not store in plastic or metal containers but in dark glass bottles.
Do not place in electromagnetic fields (next to electric cooker, TV, stereo system, etc.).
Do not refrigerate but store in a cool place.
Care and Maintenance of the Equipment
The generator is completely maintenance-free. Clean only with a damp cloth and when the power
supply unit is unplugged.
Remove deposits between the sockets occasionally.
Care of Silver Electrodes
Rub the silver electrodes with paper towels or a linen-cloth after every preparation process. Do not
use silver cleaners or scouring pads! If possible, insert the electrodes always with the same end.
Once the electrodes have the diameter of a pencil lead and could break off soon, they should be
replaced. One pair of silver electrodes is sufficient for the production of about 600 litres 5 ppm or
120 litres 25 ppm colloidal silver.
Beware of replacement silver electrodes! Our standard size 2.5 x 75 mm or 2.7 x 82 mm has
been copied several times by other manufacturers and imitations are offered as supposed original
or universal electrodes. These products rarely meet the high purity and NEVER the hardness of
the original. In order to produce accurate concentrations dense silver electrodes have to be used
(hardness in accordance with specifications of the manufacturer). The ends need to be rounded
and sanded.
Exact concentrations and optimum particle sizes can only be achieved with the original
electrodes!
Repair Malfunctions
INDICATOR LIGHT OF POWER SUPPLY UNIT DOES NOT WORK - power plug
has no contact, house fuse has gone.
DISPLAY OF THE GENERATOR DOES NOT WORK - The silver electrodes or the power supply
unit are not plugged in correctly. The electrodes are not immersed in water.
SILVER SOLUTION HAS DISCOLOURATION AT SAME PREPARATION TIME - A different kind of
water or different water temperature was used. The electrodes have been cleaned in another way.
The preparation was made at different lighting conditions. There are slight residues of detergent or
fat in the production container.
BUBBLES ARE ASCENDING ONLY ON ONE ELECTRODE - A SILVER CLOUD IS FORMING
ONLY ON ONE ELECTRODE - ONLY ONE ELECTRODE IS BECOMING BLACK - This is
completely normal in the electrolysis process.
WHITE OR GREY COLOURATION OF THE WATER - Mineral water or tap water has been used or
salt has been added. Use water with the designation “distilled” or “demineralised”. Do not add
water additives.