3/ TECHNICAL PARAMETERS
Input voltage: U
inp nom
= 230 V / 50 Hz
Maximum input voltage: 253 V
Change to battery operation: U
inp
= 180 V
Return to network operation: U
inp
= 195 V
Output voltage: 170 V
ef
, rectangular course,
mark-to-space ratio 1:4 in both polarities,
U
peak-peak
≈ 450 V
Maximum output power: 1.5 VA
Maximum input power: 10 VA
Accumulator: NiMH,
U
nom
= 10.5 V / 110 mAh
3 × 3H110BC (Vinic), or V150H (Varta)
Min. charging current: about 5 mA
Battery operation time: 4 × 180 s, for MEg40
+
Frequency synchronization with the network: for U
inp
≥ 100 V
Working conditions
Temperature: -25 °C to +50 °C
Relative humidity: 5 % to 95 %
Safety: ČSN EN 61010
Dimensions: 115 × 65 × 40 mm
Weight: 0,4 kg
Ingress protection rating: IP20
Max. cross-section of input and output wires: 3,0 mm
4/ INSTALLATION INSTRUCTIONS
e supply voltage 230 V ± 10 % with the rated frequency of 50 Hz must be brought to the
power supply MEg102 through a 200 mA fuse. e phase conductor is to be connected
to the terminal 1 of the double terminal IN and the central conductor to the terminal 2.
e output AC voltage of 170 V
ef
is on the terminals 3 and 4 of the double terminal OUT.
It is galvanically isolated from the network circuits and shall be connected to the power
supply system of the instrument MEg40
+
.
e maximum cross-section of the conductors is 3 mm. e conductors shall be with
double insulation.