SC Advance and CASHFLOW SC Diagnostic Codes (MMI LED)
LED Indicator Status You need to...
Green(Left) - Solid
Yellow(Center) - Off
Red(Right) - Off
Normal Take no action.
Green(Left) - 1 Flash
Yellow(Center) - Off
Red(Right) - Off
Disabled by machine interface Fix the machine interface (i.e. check connection).
Green(Left) - Solid
Yellow(Center) - Solid
Red(Right) - Off
Normal and cashbox cleaning
recommended
Replace with a clean cashbox
Green(Left) - 1 Flash
Yellow(Center) - 1 Flash
Red(Right) - Off
Disabled by machine interface and cashbox
cleaning recommeneded
Fix the machine interface (i.e. check connection)
and replace with a clean cashbox.
Green(Left) - Off
Yellow(Center) - Solid
Red(Right) - Off
Cashbox not seated or not present Reseat the cashbox.
Green(Left) - Off
Yellow(Center) - 1 Flash
Red(Right) - Off
Poor acceptance Clean the acceptor head.
Green(Left) - Off
Yellow(Center) - 2 Flashes
Red(Right) - Off
Jam in the acceptor Clear the jam from the note acceptor.
Green(Left) - Off
Yellow(Center) - 3 Flashes
Red(Right) - Off
Jam in the cashbox Remove the acceptor head and clear the jam from
the cashbox.
Green(Left) - Off
Yellow(Center) - 4 Flashes
Red(Right) - 4 Flashes
Cashbox cleaning required Replace with a clean cashbox.
Green(Left) - Off
Yellow(Center) - 8 Flashes
Red(Right) - 8 Flashes
Security timeout Wait for timeout to expire.
Green(Left) - Off
Yellow(Center) - Off
Red(Right) - Solid
Cashbox full Replace with an empty cashbox.
Green(Left) - Off
Yellow(Center) - Off
Red(Right) - 1 Flash
Acceptor hardware fault Replace the acceptor head with a programmed
spare.
Green(Left) - Off
Yellow(Center) - Off
Red(Right) - 2 Flashes
Interface board hardware fault Replace the interface board.
Green(Left) - Off
Yellow(Center) - Off
Red(Right) - 8 Flashes
Note timeout Wait for timeout to expire.
Green(Left) - Solid
Yellow(Center) - Solid
Red(Right) - Solid
Unprogrammed unit/Generic unit Program unit with a service tool.
Green(Left) - Flash
Yellow(Center) - Flash
Red(Right) - Flash
Unprogrammed unit/Generic unit Program unit with a service tool.
TROUBLESHOOTING
MMI Diagnostic LED Codes (Continued):

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MEI SC Advance and is the answer not in the manual?

MEI SC Advance Specifications

General IconGeneral
TypeBank Note Validator
ManufacturerMEI
ModelSC Advance
Interface OptionsSerial, USB
Power SupplyDC
Operating Voltage12V DC / 24V DC
Communication InterfaceSerial, USB

Related product manuals