PBS V5.1 Users Manual
1
In order to use this device safely and correctly, please read this manual carefully before
operating it.
Please register promptly as 10.4 in user’s manual after installation.
It is V1.2 for the version number of this user's manual.
Note:
1) Please check the power supply of adapter before charging the battery. Stop using once
the voltage of the power exceeds the scope printed on the adapter.
2) Please check the power cable of charger before charging the battery. Broken or cracked
power cable may cause a fire or electric shock which may lead to casualties.
3) Please unplug the power cable and take out the battery after charging completed.
Incomplete blackout may result in the occurrence of unusual or unsafe (Such as:
thunder strike and static electric fire, etc.)
4) Attentions before turning on the device:
a. Make sure the probe connect tightly with mainframe;
b. Make sure you have good battery, put it into battery case and lock the cover.
5) Turn off the power after finishing using.
6) Do not be away from the device while it is being used.
7) Please calibrate the date and time before first time using (or not using this device for a
long time).
8) The system will enter the energy-saving mode without any operation on the device for
about 5 minutes if not in the pre-scan mode or touch screen calibration interface. The
system will automatically shut down without any operation on the device for 10
minutes.
9) The battery should be taken out from the device if not using for a long time.
10) Stop using the device and turn it off in stormy weather; do not use the charger and cut
off the power, take out the battery in such weather.
11) Please stop charging battery and cut off power, when charging battery or using device,
if any irregularities occur as follows:
a. Abnormal noise;
b. Sudden fume or burnt odor
c. Brightness of the display screen is too high.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Meike PBSV5.1 and is the answer not in the manual?

Summary

Safety and Precautions

General Safety Notes

Essential guidelines for safe and correct device operation.

Warnings and Prohibitions

Critical warnings and prohibited actions for safe device usage.

Chapter 1 Overview

Product Features

Details the capabilities and specifications of the PBSV5.1 Palm bladder scanner.

Device Structure and Components

Describes the physical composition and parts of the device.

Intended Use and Contraindications

Specifies the device's purpose and conditions where it should not be used.

Patient Population and Side Effects

Outlines suitability for different patient groups and potential adverse effects.

Interface Symbols Explanation

Explains the meaning of various icons and symbols displayed on the device.

Acoustic Output Information

Provides technical data on the ultrasound acoustic output levels.

Chapter 2 Technical Specifications

Main Technical Specifications

Lists key technical parameters like frequency, depth, accuracy, and power.

Main Functions and Software

Details the device's primary functions and available software features.

Chapter 3 System Principle

Operating Principle

Explains how the bladder scanner operates using ultrasound and computer technology.

Hardware and Software Components

Describes the internal hardware architecture and embedded software system.

Device Visuals and Diagrams

Illustrates the device, host, and probe with diagrams and labels.

Circuit Diagram and Components

Provides technical details on the device's circuit and component list for service.

Chapter 4 Control Panel

Control Panel Layout

Identifies and explains the function of each button and the LCD screen.

Chapter 5 Environmental Requirements

Usage Environment Conditions

Specifies the temperature, humidity, and pressure suitable for device operation.

Storage and Transportation Conditions

Outlines the environmental parameters required for safe storage and transport.

Chapter 6 Device Installation

Unpacking and Initial Check

Guides users on checking contents and verifying for damage after unpacking.

Device Assembly Procedures

Step-by-step instructions for installing the battery and connecting the probe.

Chapter 7 Operation Manual

Basic Operations and Interface Navigation

Covers device preparation, power control, login, and navigating the main interface.

Scanning and Measurement Procedures

Details pre-scan, scan interfaces, result display, correction, and location prompts.

Record Management and Printing

Guides on saving, editing, browsing, printing, and exporting measurement records.

System Settings, Calibration, and Maintenance

Explains system configuration, calibration, verification, power management, and alerts.

Chapter 8 Clinical Application

Bladder Scanning Operation Steps

Provides a detailed guide on performing bladder volume scans with the device.

Bladder Profile Envelope Interpretation

Explains how to interpret the bladder contour and edge in grayscale images.

Chapter 9 Transportation and Storage

Safe Transportation Guidelines

Details requirements for handling and transporting the device safely.

Proper Storage Conditions

Specifies environmental conditions and procedures for storing the device.

Chapter 10 Maintenance and Service

Probe and Device Care

Instructions for cleaning, disinfecting, and maintaining the probe and device body.

Service and Registration

Information on obtaining service, troubleshooting, registering the device, and production date.

Chapter 11 Troubleshooting

Basic Problem Solutions

Offers simple solutions for common issues like battery, probe connection, and printer errors.

Appendix A Probe Calibration

Probe Setup and Placement

Guides on correctly positioning the probe for calibration using a phantom.

Image Analysis for Calibration

Details how to analyze pre-scan images to determine calibration adjustments.

Appendix B Volume Calibration

Calibration Setup and Phantom Parameters

Explains how to set up the system for calibration and lists phantom specifications.

Performing Volume Measurement Calibration

Step-by-step process for calibrating volume measurements using the phantom.

Appendix C 18650 Battery Safety Precautions

Battery Usage Prohibitions

Lists actions strictly forbidden when handling the 18650 battery to prevent hazards.

Recharging, Discharging, and Storage

Guidelines for safe battery charging, discharging, and long-term storage.

Battery Transportation and Other Safety

Covers safe transport of batteries and additional safety measures to prevent incidents.

Appendix D Electromagnetic Compatibility (EMC) Guidance

Electromagnetic Emissions Compliance

Provides manufacturer declarations regarding RF emissions and compliance levels.

Electromagnetic Immunity Compliance

Details compliance levels for immunity tests and recommended environments.

Meike PBSV5.1 Specifications

General IconGeneral
BrandMeike
ModelPBSV5.1
CategoryMedical Equipment
LanguageEnglish