ADJUSTMENTS
8
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Work-contacting pin does not de-
press fully - tool does not operate
Low nails
Work-contacting pin is jammed
Replenish nails
Remove battery and clear debris
Tooloperates properly, but fasteners do
not drive fully
Air pressure is too low
Depth of drive isn’t deep enough
Nail is too long for wood hardness
Increase air pressure
Adjust depth of drive
Use nail length that is appropriate for
wood
Tool operates properly,but fasteners
are driven too deep
Air pressure is too high
Depth of drive is too deep
Decrease a
ir pressure
Adjust depth of drive
Tool jams frequently Incorrect nails
Damaged nails
Loose magazine
Dirty magazine
Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine
Tool stops and LEDs flash rapidly Battery is low or has no charge
Tool is hot
Recharge battery
Allow tool to cool
Tool has charged battery and LEDs
are slowly flashing or LEDs do not turn
off after approximately ten seconds of
non-use
Tool has malfunctioned Take tool to nearest authorized repair
cen
ter
Tool will not drive a fastener or cycles
without driving a fastener
Driving mechanism is dirty Clean the nail channel as described in
the Maintenance section of the manual