Oven Clearances
A—For North American (UL/CSA) models, allow at least 2” (5.1 cm) of
clearance around
top of oven. For International (50 Hz) models, allow at least 7” (17.8 cm)
of clearance
around top of oven. Proper air flow around oven cools electrical
components.
With restricted air flow, oven may not operate properly and life of
electrical parts is
reduced.
B—Allow at least 2 9/16” (6.5 cm) between air discharge on back of oven
and back wall.
C—Allow at least 1 1/4” (3 cm) of clearance around sides of oven.
Oven Placement
• Do not install oven next to or above source of heat, such as pizza oven
or deep fat fryer. This could cause microwave oven to operate
improperly and could shorten life of electrical parts.
• Do not block or obstruct oven filter. Allow access for cleaning.
• Install oven on level countertop surface.
• If provided, place warning label in a conspicuous place close to
microwave oven.
• Outlet should be located so that plug is accessible when oven is in
place.