MAINTENANCE
SECTION 5
CMD-3967823 / 90-865237030 OCTOBER 2003 Page 87
4. Place the remote control in NEUTRAL, IDLE speed position and start the engine.
CAUTION
Do not run engine above 1500 rpm when flushing. Suction created by seawater
pickup pump may collapse flushing hose, causing engine to overheat.
5. Operate the engine at idle speed, in NEUTRAL, for about 10 minutes, or until discharge
water is clear.
6. Stop the engine.
7. Shut off the water tap.
8. Remove the adapter from the seawater pump inlet hose connection and reconnect the
seawater inlet hose. Tighten the hose clamps securely.
79464
a
b
a-Adapter
b-Seawater pump inlet hose
CAUTION
If boat is in the water, seacock must remain closed until engine is to be re-started
to prevent water from flowing back into cooling system and/or boat. If boat is not
fitted with a seacock, water inlet hose must remain disconnected and plugged to
prevent water from flowing back into cooling system and/or boat. As a
precautionary measure, attach a tag to the ignition switch or steering wheel of the
boat with the warning: Open seacock or reconnect water inlet hose before starting
engine.
NOTE: The closed cooling section of cooling system that contains coolant does not need
to be flushed. Coolant is changed at specified intervals. Refer to Maintenance Schedules.