Do you have a question about the Merlin Gerin Masterpact MP-MC and is the answer not in the manual?
Lists essential tools for installation and handling.
Provides guidelines for storing the breaker safely and optimally.
Specifies maximum permitted stacking configurations for different models.
Details the identification markings found on the circuit breaker frame.
Details the identification markings found on the stationary assembly.
Step-by-step instructions for unpacking Masterpact breakers from MP08 to MP30.
Procedures for unpacking drawout mounted breakers without the stationary assembly.
Instructions for removing the four shipping bolts during unpacking.
Steps for unpacking when only the stationary assembly is involved.
Instructions for unpacking MP40 to MP63 drawout mounted breakers.
Guidance on using lateral handles for lifting the circuit breaker.
Instructions for safely lifting the breaker using a lifting sling.
Cautions and steps for lifting the breaker using a forklift.
Specific handling instructions for the MC32 model.
Procedures and cautions for lifting MC32 breakers with slings or forklifts.
Handling instructions for MP40 to MP63 models.
Procedures and cautions for lifting MP40-MP63 breakers with slings or forklifts.
Instructions for attaching rear terminals on MP08-MP16 models.
Instructions for attaching rear terminals on MP20 model.
Instructions for attaching rear terminals on MP25-MP30 models.
Instructions for attaching rear terminals on MC32, MP40, and MP40-MC40 models.
Instructions for attaching rear terminals on MP50 and MP50-MP63-MC50 models.
Steps for performing control wiring on fixed mounted breakers.
Critical safety warning regarding control wire routing near arc chutes.
Steps for performing control wiring on drawout mounted breakers.
Information on the location of control wiring terminals.
Reiterates safety warning about control wire placement near arc chutes.
Descriptions of connected, test, disconnected, and withdrawn breaker positions.
General operational notes regarding breaker positions and operation.
Crucial note to open the breaker before disconnection.
Steps for engaging the racking crank and positioning the breaker.
Caution on handle removal and steps for breaker extraction.
Step 5: Use lateral handles to remove frame from stationary assembly.
Note: Prevent extraction if racking handle is inserted or breaker is not fully disconnected.
Steps for pulling extension rails and engaging breaker supports.
Step 3: Move breaker from withdrawn to disconnected position.
Caution: Do not press control unit while pushing breaker in.
Lists conditions required for connecting operation.
Steps for engaging the racking crank and turning it to the connected position.
Warning on force needed and step for racking crank storage.
Instructions for manual and electrical charging of the breaker's spring mechanism.
Notes on the closing coil and conditions required for breaker closing.
How to open the breaker locally and caution on fault clearing before resetting.
Methods for locking the circuit breaker frame and using a VBP padlocking device.
Steps to lock the breaker in the open and disconnected positions.
Methods for locking the stationary assembly using Kirk lock or standard padlock.
Notes on locking in disconnected or all positions.
Locking the door using a door interlock (VDP).
Note on mounting the door interlock hook on either side.
Locking shutters in storage, open, and closed positions using a padlocking device.
Interlock preventing disconnection when springs are charged; caution with trip devices.