7I92 33
REFERENCE INFORMATION
LBP16
SPACE 7: LBP READ ONLY AREA
Memory space 7 is used for read only card information. Memory space 7 is
accessed as 16 bit data.
Space 7 read with address NN5DLLHH
Space 7 read NN1D
MEMORY SPACE 7 LAYOUT:
ADDRESS DATA
0000 CardNameChar-0,1
0002 CardNameChar-2,3
0004 CardNameChar-4,5
0006 CardNameChar-6,7
0008 CardNameChar-8,9
000A CardNameChar-10,11
000C CardNameChar-12.13
000E CardNameChar-14,15
0010 LBPVersion
0012 FirmwareVersion
0014 Option Jumpers
0016 Reserved
0018 RecvStartTS 1 uSec timestamps
001A RecvDoneTS For performance monitoring
001C SendStartTS Send timestamps are
001E SendDoneTS from previous packet