8
MSM43J(T)1702020
1. With the ignition OFF and the immobiliser armed, insert the Service Key into receptable momentarily;
the LED will give one long flash.
2. Press the button of the first ID-Tag and check the immobiliser LED flashes once.
3. Repeat for the second ID-Tag.
4. Insert the service key a second time and check the immobiliser arms after 15 seconds.
5. Finally, test the operation of the immobiliser according the selected operation type; see page
‘OPERATION’.
After completing the installation and successfully testing the operation, fit the connector cover firmly into
place.