EasyManua.ls Logo

Meta System M43J - Service and ID-Tag Operation Check; Finalizing Installation

Meta System M43J
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
MSM43J(T)1702020
1. With the ignition OFF and the immobiliser armed, insert the Service Key into receptable momentarily;
the LED will give one long flash.
2. Press the button of the first ID-Tag and check the immobiliser LED flashes once.
3. Repeat for the second ID-Tag.
4. Insert the service key a second time and check the immobiliser arms after 15 seconds.
5. Finally, test the operation of the immobiliser according the selected operation type; see page
‘OPERATION’.
After completing the installation and successfully testing the operation, fit the connector cover firmly into
place.