Insulation Test Voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
---|---|
Insulation Resistance Measurement | 0.01 MΩ to 10 GΩ |
RCD Test Currents | 10mA, 30mA, 100mA, 300mA, 500mA |
PE test lead compensation | Yes |
Display | LCD |
Interface | USB |
Protection | IP54 |
Measurement Functions | Continuity, Insulation, Loop, RCD, Voltage |
RCD Type | Type AC, Type A |
Frequency Measuring Range | 45 Hz to 65 Hz |
Memory | 1000 measurements |
Power Supply | 6 x 1.5 V AA batteries |
Safety Standards | IEC 61010-1 |
Dimensions | 70 mm |
General safety warnings and precautions for instrument use.
Information on battery type, charging, and safety precautions.
Lists standards and regulations the instrument complies with.
Description and legend for the instrument's front panel controls.
Details of the instrument's input and output connectors.
Description of the instrument's back panel, including battery/fuse compartment.
Methods for carrying the instrument using the provided strap.
Lists standard and optional accessories included with the instrument.
Explanation of instrument display elements, indicators, and sound signals.
How to select measurement functions and navigate the instrument.
How to configure instrument settings like language, date, and RCD standards.
How to measure voltage, frequency, and determine phase sequence.
Procedure for measuring insulation resistance according to standards.
Measuring earth connection and bonding resistance for safety.
Procedures for testing Residual Current Devices (RCDs).
Measuring fault loop impedance and calculating prospective fault current.
Measuring line impedance, short-circuit current, and voltage drop.
Procedure for measuring earth resistance using a 3-wire method.
Functionality and safety for the PE test terminal.
Measuring PE conductor resistance on the MI 3100 SE.
How measurement results are organized in the instrument's memory.
Details on the 4-level memory structure for data storage.
Procedure for saving measurement results to the instrument's memory.
How to retrieve stored measurement results from memory.
Procedures for deleting stored test results and memory content.
How to transfer data to a PC via USB, RS232, or Bluetooth.
Instructions for replacing the instrument's fuses.
How to clean the instrument's housing and accessories.
Importance and procedure for periodic instrument calibration.
Information on how to contact for repairs and service.
Detailed technical specifications for insulation resistance measurements.
Technical specifications for continuity measurements (R LOW, CONTINUITY).
Technical specifications for RCD testing functions.
Technical specifications for fault loop impedance and fault current.
Technical specifications for line impedance, short-circuit current, and voltage drop.
Technical specifications for PE conductor resistance measurement.
Technical specifications for earth resistance measurement.
Technical specifications for voltage, frequency, and phase rotation measurements.
General technical specifications including power, dimensions, and operating conditions.