EasyManua.ls Logo

METREL MI 3100 SE EurotestEASI User Manual

METREL MI 3100 SE EurotestEASI
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
EurotestEASI
MI 3100 SE
MI 3100 s
Instruction manual
Version 1.3.2., Code no. 20 752 131

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the METREL MI 3100 SE EurotestEASI and is the answer not in the manual?

METREL MI 3100 SE EurotestEASI Specifications

General IconGeneral
Insulation Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Insulation Resistance Measurement0.01 MΩ to 10 GΩ
RCD Test Currents10mA, 30mA, 100mA, 300mA, 500mA
PE test lead compensationYes
DisplayLCD
InterfaceUSB
ProtectionIP54
Measurement FunctionsContinuity, Insulation, Loop, RCD, Voltage
RCD TypeType AC, Type A
Frequency Measuring Range45 Hz to 65 Hz
Memory1000 measurements
Power Supply6 x 1.5 V AA batteries
Safety StandardsIEC 61010-1
Dimensions70 mm

Summary

Preface

Safety and operational considerations

Warnings and notes

General safety warnings and precautions for instrument use.

Battery and charging

Information on battery type, charging, and safety precautions.

Standards applied

Lists standards and regulations the instrument complies with.

Instrument description

Front panel

Description and legend for the instrument's front panel controls.

Connector panel

Details of the instrument's input and output connectors.

Back side

Description of the instrument's back panel, including battery/fuse compartment.

Carrying the instrument

Methods for carrying the instrument using the provided strap.

Instrument set and accessories

Lists standard and optional accessories included with the instrument.

Instrument operation

Display and sound

Explanation of instrument display elements, indicators, and sound signals.

Function selection

How to select measurement functions and navigate the instrument.

Settings

How to configure instrument settings like language, date, and RCD standards.

Measurements

Voltage, frequency and phase sequence

How to measure voltage, frequency, and determine phase sequence.

Insulation resistance

Procedure for measuring insulation resistance according to standards.

Resistance of earth connection and equipotential bonding

Measuring earth connection and bonding resistance for safety.

Testing RCDs

Procedures for testing Residual Current Devices (RCDs).

Fault loop impedance and prospective fault current

Measuring fault loop impedance and calculating prospective fault current.

Line impedance and prospective short-circuit current / Voltage drop

Measuring line impedance, short-circuit current, and voltage drop.

Earth resistance

Procedure for measuring earth resistance using a 3-wire method.

PE test terminal

Functionality and safety for the PE test terminal.

PE conductor resistance (MI 3100 SE only)

Measuring PE conductor resistance on the MI 3100 SE.

Auto-sequences (MI 3100 SE only)

Data handling (MI 3100 SE only)

Memory organization

How measurement results are organized in the instrument's memory.

Data structure

Details on the 4-level memory structure for data storage.

Storing test results

Procedure for saving measurement results to the instrument's memory.

Recalling test results

How to retrieve stored measurement results from memory.

Clearing stored data

Procedures for deleting stored test results and memory content.

Communication

How to transfer data to a PC via USB, RS232, or Bluetooth.

Upgrading the instrument

Maintenance

Fuse replacement

Instructions for replacing the instrument's fuses.

Cleaning

How to clean the instrument's housing and accessories.

Periodic calibration

Importance and procedure for periodic instrument calibration.

Service

Information on how to contact for repairs and service.

Technical specifications

Insulation resistance

Detailed technical specifications for insulation resistance measurements.

Continuity

Technical specifications for continuity measurements (R LOW, CONTINUITY).

RCD testing

Technical specifications for RCD testing functions.

Fault loop impedance and prospective fault current

Technical specifications for fault loop impedance and fault current.

Line impedance and prospective short-circuit current / Voltage drop

Technical specifications for line impedance, short-circuit current, and voltage drop.

PE conductor resistance (MI 3100 SE only)

Technical specifications for PE conductor resistance measurement.

Resistance to earth

Technical specifications for earth resistance measurement.

Voltage, frequency, and phase rotation

Technical specifications for voltage, frequency, and phase rotation measurements.

General data

General technical specifications including power, dimensions, and operating conditions.

Related product manuals