49
4
electric
current
over limit
electric current
over limit of
motor
Check motor and
relative wiring
connections
Switch off and wait a
few minutes and
Switch on.
5
Freewheel
level issue
The freewheel
level is on
Check the relative
wiring of the
freewheel level
Confirm the level is
on the correct
position
6
Accelerate
the
variable
resistor
issue
When turning on
the controller,
accelerate variabl
e resistor isn’t
on the neutral
position
Make sure the
accelerate variable
resistor is on the
neutral position
Accelerate variable
resistor may need to
recalibration.
7
Speed
limited
variable
resistor
issue
accelerate variable
resistor, Speed
limited variable
resistor or other
wiring issue
Check all the
accelerate variable
resistor, Speed
limited variable
resistor or other
wiring
8
Motor
voltage
issue
Motor and other
relative wirings
issue
Check Motor and
other relative
wirings
9
Other
issues
Some inner
issues in the
controller
Check all the
connection and
wirings
10
Pushing/
Slipping
issues
The speed of
pushing or
slipping is over
limited
Switch off and on the
controller