EasyManuals Logo
Home>Meyer Sound>Speakers>DS-2P

Meyer Sound DS-2P User Manual

Meyer Sound DS-2P
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
7
The DS-2P performs within its acoustical specifications
and operates at a normal temperature if the TPL LED is
on for no longer than two seconds, and off for at least
one second. If the LED remains on for longer than three
seconds, the DS-2P is hard limiting with these negative
consequences:
Increasing the input level will not increase the
volume.
The system distorts due to clipping and nonlinear
driver operation.
The life-span of driver and amplifier components is
reduced because they are subjected to excessive
heat.
The TPL LED can indicate an imbalance in a system of
speakers by functioning like a spectrum analyzer. If
speakers in a subwoofer, mid-bass, or mid-hi subsystem
begin to limit before reaching the required operating
level for the entire system, then that subsystem needs to
be supplemented with additional speakers.
NOTE: Although the TPL limiters exhibit smooth sonic
characteristics, we do not recommend using them for
intentional compression effects. Use an outboard
compressor/limiter to compress a mixed signal.
Driver Excursion Clamp
The drivers in the DS-2P are protected from over-
excursion by an excursion clamping circuit that does
not have attack or release time constants. The circuit
provides instantaneous braking for the drivers without
the pumping effects commonly produced by compressor/
limiters.
The circuit uses sophisticated filters to minimize the
distortion normally caused by clamping and clipping.
As the DS-2P’s input signal is increased past the clamp-
ing point, the output signal remains at a fixed level,
protecting the drivers and minimizing negative sonic
effects. The DS-2P operates safely if the Exc. Clamp LED
is on for no longer than two seconds, and off for at least
one second.
Fans and Cooling System
The DS-2P uses a forced-air cooling system with two
fans to prevent the amplifiers from overheating. The
fans draw air in through ducts on the front of the cabinet,
over the heatsinks, and out the rear of the cabinet. Since
dust does not accumulate in the amplifier circuitry, its
life-span is increased significantly.
A foam insert filter, in combination with the entire front
grill surface, acts as an air filter for the cooling system.
Despite the filtering, extensive use or a dusty operating
environment can allow dust to accumulate along the
path of the airflow, preventing normal cooling. We
recommend periodically removing the grill, filter, and
amplifier module and using compressed air to clear
dust from the grill, filter, fans, and heatsinks. Make sure
that the air ducts are clear and that there is at least six
inches clearance for exhaust behind the cabinet.
heatsinks
power
supply
air
intake
air
intake
cooling fans
A variable-speed primary fan runs continuously with an
inaudible operating noise of 22 dBA at 1 m at its slowest
speed. The speed of the primary fan begins increasing
when the temperature of the heatsinks reaches 42°C.
The fan reaches full speed at 62°C and is barely audible
near the cabinet, even without an audio signal.
In the unusual event that the heatsink temperature reaches
74°C, the secondary fan turns on; it turns off when the
temperature decreases to 68°C. The secondary fan is
audible at close proximity without an audio signal and
turns on in response to
primary fan failure (check its status immediately);
accumulation of dust in the cooling system path;
a prolonged period of high source levels in hot
temperatures or direct sunlight;
driver failure.
TROUBLESHOOTING NOTE: In the highly unlikely event
that the secondary fan does not keep the temperature
below 85
°
C, the DS-2P automatically shuts down until
AC power is removed and reapplied. If the DS-2P shuts
down again after cooling and reapplying AC power,
contact Meyer Sound for repair information.

Other manuals for Meyer Sound DS-2P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meyer Sound DS-2P and is the answer not in the manual?

Meyer Sound DS-2P Specifications

Acoustical IconAcoustical
frequency response± 4 dB 50 – 160 Hz
phase response± 60° 60 – 200 Hz
maximum SPL (music as source)140 peak
maximum SPL (pink noise as source)136 dB continuous; 140 peak
dynamic range> 120 dB
coverage120° H x 120° V
Transducers IconTransducers
low frequency transducerTwo 15" diameter MS-15 cone
Audio Input IconAudio Input
input type impedance10 kΩ
connectorXLR (A-3) male and female
nominal input level+4 dBu (1.23 Vrms)
Amplifiers IconAmplifiers
amplifier typeComplementary power MOSFET output stages class AB/H
burst capability1240 Watts (620 Watts per channel)
THD, IM, TIM< .02 %
AC Power IconAC Power
connector250 V NEMA L6-20P / IEC 309 Twistlock male receptacle
automatic voltage selection85 – 134 V / 165 – 264 V; 50 Hz / 60 Hz
max continuous RMS current (115 V)8 A
max continuous RMS current (230 V)4 A
max continuous RMS current (100 V)10 A
max burst RMS current (115 V)15 A
max burst RMS current (230 V)8 A
max burst RMS current (100 V)18 A
max peak current during burst (115 V)22 Apk
max peak current during burst (230 V)11 Apk
max peak current during burst (100 V)25 Apk
soft-current turn-on inrush current< 12A @115V
Physical IconPhysical
dimensions21.25” W x 56.75” H x 30” D
weight221 lb (100 kg)
shipping weight267 lb (121 kg)

Related product manuals