Directly delete the number:
SOS,D,13800138000#
Delete 1st number: SOS,D,1#
Delete 2nd number: SOS,D,2#
Delete the 2nd and 3rd number: SOS,D,2,3#
Example: SHIFT,ON,100,1# ( Means Setting 100
meters shift alarm range, when the ignition turned
off, vehicle’s 100 meters’ shift will trigger the alarm.)
Example: SPEED,ON,120,1# ( Means the speed limit is
120km/h and the alarm way is via SMS and Server )
A=ON/OFF, open or close over speed alarm,
default: OFF
B=1255(km/h), speed limit, default100(km/h);
M=0/1/2, way of alarm, 0 : SERVER only, 1: SERVER+
SMS, 2: SERVER+SMS+CALL; default: 1
Example: SENALM,ON,2# ( Means the vibration alarm
already been enabled and the alarm message will be
sent via Server, SMS and Call )
A=ON/OFF, default: OFF;
M=0/1/2, way of alarming, 0 :GPRS only, 1: SMS+GPRS,
2: GPRS+SMS+phone call, default:1
A
=ON/OFF; default:ON
B=Shift Distance (Range: 100-9999m)
M=0/1/2; way of alarm, 0 : GPRS only,
1: SMS+GPRS, 2: GPRS+SMS+CALL, default:1
Shift Alarm Setting
Vibration
Alarm Setting
Overspeed
Alarm Setting
SPEED,A,B,M#
SENALM,A,M#
SENALM,OFF# CANEL VIBRATE ALARM OK
SHIFT,A,B,M#
SHIFT,OFF#
CANCEL SHIFT ALARM OK
Functions Command Format
Explanation
ACC Status
Change Alarm
Power
Disconnect Alarm
ACCALM,A,B,M#
ACCALM,OFF#
PWRALM,A,M#
PWRALM,OFF#
Cancel ACC alarm function
Close power disconnect alarm
Example: PWRALM,ON,2# (Means if the external power
disconnect the tracker will send alarm message out
via Server, SMS and Call)
A=ON/OFF, default ON;
M=0/1/2, ways of alarming, 0: Serveronly,
1: SMS+Server, 2 : SMS+Server+Call, default:2
Example: ACCALM,ON,0,2# (Means the tracker will
send alarm message out via Server, SMS and Call when
the engine is start)
A=ON/OFF, Default: ON;
B: 0/1/2; 0: ACC ON Alarm; 1: ACC OFF
Alarm; 2: ACC ON&OFF Alarm; Default:2
M: 0/1/2 (way of alarm): 0 : Server only,
1: SMS+Server, 2: SMS+Server+Call, Default:1;