EasyManua.ls Logo

Micom Autodoor EDM-MD Series - User Manual

Micom Autodoor EDM-MD Series
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EDM-MD Series
Installation Manual
Page 1
MICOM AUTODOOR
Automatic Sliding Door Operator
Model: EDM MD
Original Instructions
EN16005 Compliant
INSTALLATION MANUAL
OSAKA JAPAN
www.micomautodoor.com
REVISED DATE: JUNE 2014 No. MD0001 Ver1
Question and Answer IconNeed help?

Do you have a question about the Micom Autodoor EDM-MD Series and is the answer not in the manual?

Summary

Product Description

Introduction

Overview of the EDM-MD Series automatic sliding door operator.

EN16005 Compliance

Details on EN16005 compliance for the MICOM SMB system.

Delivery

Information on various formats the MICOM EDM-MD Series can be supplied.

MICOM EDM MD Series

EDM MD Complete Operator Parts

Identification of all parts included in the complete EDM MD operator.

EDM MD - SENSOR & BATTERY MONITORING BOARD (SMB) - EN16005 COMPLIANCE

Details on the Sensor & Battery Monitoring Board (SMB) for EN16005 compliance.

SMB - Function Selector Switch - 4 Position Key

Explanation of the 4-position key operated Function Selector Switch for SMB.

Installation

Base Rail Installation

Instructions for positioning and installing the base rail for the automatic door.

EDM MD - Side View Section

Technical drawing showing a side view section of the EDM MD operator.

EDM-MD Front View

Technical drawing illustrating the front view of the EDM MD operator.

Mounting Doors

Steps for mounting the doors onto the operator system.

Smooth Operation

Checks to ensure smooth and noise-free operation of the door.

Power On

Pre-checks before switching on the power to the operator.

Teaching; Learning Operation

Teaching; Learning

Procedure for memorizing the door stroke via a teaching or learning cycle.

Set Up & Operation

Motor Gear Box Assembly EDM MD

Identification of the motor gear box assembly components.

Control Box Assembly EDM MD

Overview and functions of the control box assembly.

Setting

Basic Setting Code (Set the slide switch to PROGRAM)

Basic setting codes and adjustments using LED1 and LED2.

Hold Open Time

Configuration of the time the door remains in the open position.

Partial Open (Energy Saving) %

Setting the partial open width for energy saving.

Open Delay (E-Lock)

Setting the delay time for the E-Lock function.

Obstruction Detection

During closing travel

How the system reacts to obstructions during the closing cycle.

During Opening travel

How the system reacts to obstructions during the opening cycle.

Optional Accessories

MICOM Function Selector Switches - 4 Positions with Rotary Knob

Details on the 4-position rotary knob function selector switch.

Wiring Drawing - MICOM Function Selector Switch

Wiring diagram for the MICOM Function Selector Switch.

Rotary Function Selector Switch - 4 Positions with Push Button - Exit

Details on the 4-position push button function selector switch.

Overview

The MICOM AUTODOOR EDM-MD Series is an economical automatic sliding door solution designed for easy open and close operation, offering variable function adjustment for single or double door leaves up to 100kg per leaf. Installation and setup are simplified, with door stroke memorized by simply pushing the RESET button once during initial installation or for servicing.

Function Description

The EDM-MD Series is an automatic sliding door operator that provides safe and reliable operation. It incorporates a sensor or switch activation with safety beam threshold safety input, ensuring the doors operate safely. The system supports various functions and parameters, which can be adjusted to suit individual installations through an easily accessible LED visual display found on the EDM-MD Control Box. Connections for sensors and other inputs are located on an independent input terminal on the rail or by adding a MICOM Sensor and Battery Monitoring board (SMB) for EN16005 Compliance.

The system features a comprehensive set of functions for controlling door movement, safety, and operational modes. These include:

  • Door Operation: Open High Speed (500mm/s MAX), Open Low Speed, Close High Speed (400mm/s MAX), Close Low Speed, Open Force, Close Force, Open Brake Force, Close Brake Force, Partial Open Width, and Open Delay Time.
  • Safety Features: Safety Beams (MUST be installed to ensure threshold safety), obstruction detection, and a sensor/threshold safety system using microwave or infrared detection sensors and safety beam products.
  • Operational Modes: The system supports various operational modes, including Closed/Locked, Exit Only, Automatic, and Hold Open. These modes can be selected via a 4-position rotary knob or a push button.
  • Emergency Features: An Anti-Panic function ensures doors are closed by hand after battery open. The system also supports an emergency open input and a 24VDC power input (isolated transformer) for continuous operation during power outages.
  • Monitoring and Control: The EDM-MD Control Box features an LED display for visual feedback on the system's status and parameters. It includes a RUN/PRG switch for programming, TEST/UP & SET buttons for adjustments, and indicators for power, sensor status, and error codes.

Important Technical Specifications

  • Power Consumption: 200-240V AC, 0.7A
  • Door Weight (max): Single leaf: 100kg, Double leaf: 100kg x 2
  • Manual Door Opening/Closing Force (during power failure): 24.5 ~ 39.2N (2.5 ~ 4kgf) for MD-S, 29.4 ~ 49.0N (3~5kgf) for MD-D.
  • Open Door Speed: Adjustable 160 - 500mm/s
  • Close Door Speed: Adjustable 160 - 400mm/s
  • Brake Adjustment: 0-F value (16 steps adjustable)
  • Partial Open: 35%, 50%, 65%, 80% (4 steps adjustable)
  • Motor: DC 24V / 55W Brushless
  • Operating Temp & Humidity: 0°C ~ 50°C / 30% - 85%
  • Compliance: CE & EN16005 COMPLIANT (European Regulation – Option outside of EU). The SMB (Sensor & Battery Monitoring Board) is specifically designed for EN16005 compliance.
  • Dimensions: Base rail length: Single Leaf - 2100mm, Double Leaf - 4200mm. Full Kit: Single Leaf - 2100mm, Double Leaf - 4200mm. Rail & Cover Materials Only: Single Leaf - 2100mm, Double Leaf - 4200mm. SHORT KIT (Retro-Fit VII- ZII/GII Rail UNDER DEVELOPMENT): Single Leaf - 2100mm, Double Leaf - 4200mm.

Usage Features

  • Easy Installation: The installation process is designed to be straightforward, with the door stroke being memorized by a simple RESET button push.
  • Adjustable Parameters: Various parameters such as door speed, force, partial open width, and delay times can be easily adjusted through the control box using the TEST/UP & SET buttons and the LED display.
  • Multiple Operation Modes: The system offers flexible operation modes (Closed/Locked, Exit Only, Automatic, Hold Open) to suit different security and access control requirements. These modes can be selected via a rotary knob or push button.
  • User-Friendly Interface: The LED display on the control box provides clear visual feedback on the system's status, including power, sensor input, error indications, and DIP switch settings.
  • Power On/Off Control: The power switch is located to the right of the motor, fixed to the underside of the base rail, allowing for easy control of the system's power.
  • Teaching/Learning Operation: The controller can memorize the door stroke by a teaching or learning stroke. This process involves setting the slide switch to "PROG" and then pressing "UP" & "SET" buttons to initiate the learning sequence.

Maintenance Features

  • Clearance and Adjustment: Regular checks are required for floor clearance, hanger roller brackets, and door alignment to ensure smooth and quiet operation. Adjustments can be made to hanger roller brackets, door mounts, and door height for proper clearance.
  • Error Indication: The LED display provides error codes (E1: Open error, E2: Closer error, E4: Loose belt, E6: E-lock error) to help diagnose and troubleshoot issues quickly.
  • Power Supply Monitoring: The system monitors the power supply, and in case of a malfunction or event affecting stored data, the controller can be recovered by another RESET.
  • Protective Measures: Safety beams and obstruction detection features are crucial for preventing injury and damage. Regular checks of these systems are essential.
  • Component Accessibility: Key components like the motor gear box, control box, and various sensors are designed for accessibility to facilitate maintenance and repairs.
  • Protective Gloves: Protective gloves should be worn when handling metal parts during maintenance to prevent injury.
  • Safe Working Area: A safe working area should be maintained by cordon or other temporary boundary to prevent risk of crushing or impact by a falling door panel or other solid object onto a person.

Micom Autodoor EDM-MD Series Specifications

General IconGeneral
BrandMicom Autodoor
ModelEDM-MD Series
CategoryGarage Door Opener
LanguageEnglish

Related product manuals