EasyStart Home AC Wiring
Using Micro-Air ASY-364 or ASY-368
Contents
Safety and Warnings ..................................................................................................................................... 2
Installing EasyStart ........................................................................................................................................ 3
Step 1: Identify the components .............................................................................................................. 3
Step 2: Mounting the unit ......................................................................................................................... 3
Step 3: Identify the capacitor terminals ................................................................................................... 4
Three terminal run capacitors............................................................................................................... 4
Two terminal run capacitors ................................................................................................................. 4
Step 4: Removing start devices ................................................................................................................. 5
Step 5: Check for compressor monitoring systems .................................................................................. 5
Step 6: Connecting the ORANGE wire ....................................................................................................... 5
Step 7: Connecting the BROWN wire ........................................................................................................ 6
Step 8: Connecting the WHITE wire .......................................................................................................... 6
Step 9: Connecting the BLACK wire .......................................................................................................... 7
Step 10: Learning ...................................................................................................................................... 7
Appendix 1: Compressor monitoring system changes ................................................................................. 8
Models without Bluetooth ........................................................................................................................ 8
Models with Bluetooth ............................................................................................................................. 8
Appendix 2: Maintenance ............................................................................................................................. 9
Appendix 3: Additional Resources ................................................................................................................ 9
Question and Answer IconNeed help?

Do you have a question about the MICRO-AIR EasyStart Home and is the answer not in the manual?

MICRO-AIR EasyStart Home Specifications

General IconGeneral
BrandMICRO-AIR
ModelEasyStart Home
CategoryController
LanguageEnglish

Summary

Safety and Warnings

General Safety Precautions

Highlights electrical hazards, professional installation, power disconnection, reading instructions, and capacitor discharge.

Installing EasyStart

Identify Components

Locate the run capacitor and contactor within the air conditioner unit for connection.

Mounting the Unit

Details mounting the EasyStart on any flat surface, horizontally or vertically.

Identify Capacitor Terminals

Explains how to identify terminals on 3-terminal and 2-terminal run capacitors using labels or wire tracing.

Remove Start Devices

Guides on identifying and removing start assist devices connected to the HERM terminal.

Check Compressor Monitoring Systems

Addresses systems monitoring compressor start-up and potential need to adjust EasyStart settings.

Connect ORANGE Wire

Instructions for connecting the EasyStart ORANGE wire to the HERM terminal.

Connect BROWN Wire

Details connecting the EasyStart BROWN wire to the disconnected C terminal wire.

Connect WHITE Wire

Instructions for connecting the EasyStart WHITE wire to the contactor screw.

Connect BLACK Wire

Guides on connecting the EasyStart BLACK wire to the contactor.

Learning Process

Steps to initiate the air conditioner to complete the EasyStart learning cycle.

Appendix 1: Compressor Monitoring System Changes

Models without Bluetooth

Details jumper and JP2 modifications on the circuit board for non-Bluetooth models.

Models with Bluetooth

Explains using a mobile app to configure Bluetooth settings for Bluetooth models.

Appendix 2: Maintenance

Cleaning and Durability

Information on the box's water-tightness and recommended cleaning methods.

Appendix 3: Additional Resources

Website Information

Provides the website address for further information, troubleshooting, or assistance.