8008_inst.7/7/04.qx
AUXILIARY OUTPUT PLUG
GREY: AUXILIARY OUTPUT CHANNEL #1: (PROGRAMMABLE)
This Programmable Auxiliary Channel Will Provide A Momentary (-) Negative Output When The “AUX” Button On The
Remote Control Is Pressed Momentarily. (See Programming Section: Vector #4)
This Auxiliary Output Has 2 Programmable Settings:
1) TRUNK/HATCH RELEASE WITH DISARM. (DEFAULT)
• This Setting Will Automatically Disarm The Alarm & Provide A Momentary (-) Pulse For A Trunk/Hatch Release.
(SEE DIAGRAM)
2) HIGH SECURITY CAR-START INTERFACE: (MUST BE PROGRAMMED)
• This Programmable Setting Is Designed To Activate A Car-Start Module Without Having To Disarm The Alarm,
Maintaining High Security While The Vehicle Is Running.
• This Setting Will Provide A Momentary (-) Pulse To Activate A Car-Start Module And Automatically By-Pass
The Sensor Zone When The Ignition Turns “ON” To Prevent False Alarms. (No Sensor By-Pass Relay Necessary).
The Door/Hood/Trunk Zones Remain Fully Armed.
• If The Alarm Is Triggered While The Vehicle Is Running, A Pulse Will Be Sent To The Car-Start Module To Turn
The Vehicle “OFF”.
CONNECT To A Car-Start Module’s (-) Activation Input Wire.
GREY/WHITE: AUXILIARY OUTPUT CHANNEL #2: (PROGRAMMABLE)
This Programmable Auxiliary Channel Will Provide A CONSTANT or LATCHED (-) Negative Output When Buttons “LOCK
& PANIC” On The Remote Control, Are Pressed Momentarily. (See Programming Section: Setting #4)
This Auxiliary Output Has 2 Programmable Settings:
1) CONSTANT OUTPUT: (DEFAULT)
• This Setting Will Provide A Constant (-) Negative Output. As Long As
The Buttons are Held Down.
2) LATCHED 30 SECOND OUTPUT: (MUST BE PROGRAMMED)
• This Setting Will Provide A (-) Negative Latched Output For 30 Seconds.
• This Latched Output Will Reset Anytime The Remote Control Is Used.
GREY/BLACK: AUXILIARY OUTPUT CHANNEL #3:
This Auxiliary Channel Will Provide A Constant (-) Negative Output When Buttons “UNLOCK & AUX” Are Pressed & Held
For 2 Seconds.This Output Will Remain Constant As Long As The Buttons Are Held