Making
Measurements
4.
Connect
the
probe
to
the
semiconductor
device
you
0
to
check
and
note
the
meter
reading.
5.
Reverse
the
probes
and
note
the
second
reading.
If
the
first
reading
shows
some
value
and
second
is
overrange,
the
device
is
good.
If
both
are
overrange,
the
device
is
open.
If
the
reading
are
both
very
small
or
zero,
the
device
is
shorted.
Note:
The
values
indicated
on
the
display
during
the
diode
check
operation
shows
the
actual
forward
voltage
(max.
2V).
If
the
value
is
around
0.400
the
device
is
germanium
type:
if
it
is
around
0.600
the
device
is
silicon
type.
An
LED
will
make
the
meter
display
a
value
of
about
1.800.
=)