4
An additional Carry Out or Overflow output can be enabled.
Normal Mode Features:
Configurable operand widths for A0 and B0 between 2 and 18
Configurable operand width for C between 2 and 44
Optional assignment of operand A0 to an 18 bit two's complement constant
Optional assignment of operand C to a 44 bit two’s complement constant
Option to select between Multiplier followed by Adder, Subtractor or dynamic AddSub
Optional Arithmetic Right Shift by 17 bits of the feedback input
Dot Product Mode Features:
Configurable operand widths for A0, B0, A1, B1 between 2 and 9.
Configurable operand width for C between 2 and 35.
Optional assignment of operand A0 and A1 to a 9 bit two's complement constant
Optional assignment of Operand C to a 35 bit two’s complement constant