3
-20~60℃(Exd
Storage Temperature:-40~120,-20~85cable type
Resistance:≤U-11/0.02Ω2-wire; ≥10kΩ3-wire
Pressure Port:M20×1.5 Male with Waterline Seal
Intrinsic safe version mark:ExiaIICT6Ga(only for 2-wire);
ExiaIICT4Ga(ATEX)
EC-Type Examination Certificate Number: Presafe 17 ATEX 11284X
Intrinsically safe coefficient:
Ui=28VDC Ii=93mADC Li=0mH Ci=0.042uF Pi=0.65W
ATEX:
Ui=28VDC Ii=115mADC Li=0mH Ci=0.055uF Pi=0.66W (2-wire)
Ui=26VDC Ii=140mADC Li=0mH Ci=0.055uF Pi=0.66W (3-wire)
Housing Protection: Plug ConnectionIP65
Cable ConnectionIP65
3 Outline Construction and Installation
Unit:mm
3.1 Construction and Mounting
Dimension see Fig. 1