T2
T1
T2
T2
T1
T1 + T2
Set detect distance in
mm or cm
For single detect
point press T2
until »- - -« is
displayed
Choose » « for NCC or
» « for NOC
T1
T2
For window mode
operation set far
detect point in
mm or cm
T1 + T2
Press T1 and T2 simultaneously for about
3 s until welcome message has passed
T1 + T2
T2
T1
T1 + T2
T1 + T2
T1 + T2
T2
T1
Set switched output
Ready
Start here
Set sensor parameters alternatively numerically using LED-display...
Product description
The mic+sensor with one switched output
measures the distance to an object within
the detection zone contactless. Depen-
ding on the adjusted detect distance the
switched output is set.
All settings are done with two push-but-
tons and a three-digit LED-display
(TouchControl).
Light emitting diodes (three-colour LEDs)
indicate the switching status.
The output functions are changeable
from NOC to NCC.
The sensors are adjustable manually using
the numerical LED-display or may be trai-
ned using Teach-in processes.
Useful additional functions are set in the
Add-on-menu.
Using the LinkControl adapter (optional
accessory) all TouchControl and additio-
nal sensor parameter settings may be
made by a Windows-Software.
Important instructions for assembly and
application
All employee and plant safety-relevant
measures must be taken prior to assembly,
start-up, or maintenance work (see operation
manual for the entire plant and the operator
instruction of the plant).
The sensors are not considered as safety
equipment and may not be used to ensure
human or machine safety!
The mic+ sensors indicate a blind zone, in
which the distance cannot be measured. The
operating range indicates the distance of the
sensor that can be applied with normal re-
flectors with sufficient function reserve.
When using good reflectors, such as a calm
water surface, the sensor can also be used up
to its maximum range. Objects that strongly
absorb (e.g. plastic foam) or diffusely reflect
sound (e.g. pebble stones) can also reduce
the defined operating range.
Synchronisation
If the assembly distances shown in Fig.1 for
two or more sensors are exceeded the inte-
grated synchronisation should be used. Con-
nect Sync/Com-channels (pin 5 at the units re-
ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-
chronisation/multiplex
Multiplex mode
The Add-on-menu allows to assign an indivi-
dual address »01« to »10« to each sensor
connected via the Sync/Com-channel (Pin5).
The sensors perform the ultrasonic measure-
ment sequentially from low to high address.
Therefore any influence between the sensors
is rejected.
The address »00« is reserved to synchronisa-
tion mode and deactivates the multiplex
mode. (To use synchronised mode all sensors
must be set to address »00«.)
0.35 m
0.40 m
2.50 m
2.50 m
1.10 m
2.00 m
8.00 m
18.00 m
4.00 m
30.00 m
Assembly instructions
Assemble the sensor at the installation lo-
cation.
Plug in the connector cable to the M 12
connector.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable
Start-up
mic+ sensors are delivered factory made with
the following settings:
Switched output on NOC
Detecting distance at operating range
and half operating range
Measurement range set to maximum ran-
ge
1
3
colour
+U
B
-U
B
brown
blue
4
2
5
D
-
black
white
Sync/Com. grey
1
5
2
34
Set the parameters of the sensor manually or
use the Teach-in procedure to adjust the
detect points.
Fig. 3: TouchControl
Operation
mic+sensors work maintenance free. Small
amounts of dirt on the surface do not influ-
ence function. Thick layers of dirt and caked-
on dirt affect sensor function and therefore
must be removed.
Note
mic+sensors have internal temperature
compensation. Because the sensors heat
up on their own, the temperature com-
pensation reaches its optimum working
point after approx. 30 minutes of operati-
on.
During normal mode operation, a yellow
LED D2 signals that the switched output
has connected.
During normal mode operation, the mea-
sured distance value is displayed on the
LED-indicator in mm (up to 999 mm) or
cm (from 100 cm). Scale switches auto-
matically and is indicated by a point on
top of the digits.
During Teach-in mode, the hysteresis
loops are set back to factory settings.
If no objects are placed within the detec-
tion zone the LED-indicator shows »- - -«.
If no push-buttons are pressed for 20 se-
conds during parameter setting mode the
made changes are stored and the sensor
returns to normal mode operation.
You can lock the key pad to provide in-
puts, see »Key lock and factory setting«.
You can reset the factory settings at any
time, see »Key lock and factory setting«.
Show parameters
Tapping push-button T1 shortly during nor-
mal mode operation shows »PAr« on the
LED-display. Each time you tap push-button
T1 the actual settings of the switched output
are shown.
Operating manual
mic+ Ultrasonic Sensors with
one switched output
c
m m
m
%
T
1
D
1
D
2
T
2
measuring range
LED D1 and D2
3-digit
LED-display
Push-buttons T1 and T2
mic+25/D/TC mic+25/E/TC
mic+35/D/TC mic+35/E/TC
mic+130/D/TC mic+130/E/TC
mic+340/D/TC mic+340E/TC
mic+600/D/TC mic+600/E/TC
2014/30/EU
HM 1909
Question and Answer IconNeed help?

Do you have a question about the Microsonic mic+ and is the answer not in the manual?

Microsonic mic+ Specifications

General IconGeneral
Protection classIP67
ConnectionM12 plug
Supply voltage9 – 30 V DC
Operating Temperature-25 °C ... +70 °C
Housing materialPBT

Summary

Product Description and Features

Touch Control Operation

Describes setting parameters using two push-buttons and a three-digit LED-display.

Switching Status Indicators

Explains how three-colour LEDs indicate the sensor's switching status.

Output Functionality

Details the ability to change output functions between Normally Open Contact (NOC) and Normally Closed Contact (NCC).

Sensor Adjustment Methods

Covers manual adjustment via LED-display and Teach-in processes.

Add-on Menu Functions

Highlights additional functions available through the Add-on menu.

Software Parameter Control

Explains using a Link Control adapter and Windows software for parameter settings.

Assembly and Application Instructions

Safety Precautions

Emphasizes taking plant safety-relevant measures before assembly, start-up, or maintenance.

Non-Safety Equipment Warning

States sensors are not safety equipment and must not be used for human or machine safety.

Operating and Blind Zones

Explains sensor blind zones and operating range with different reflectors.

Sensor Synchronisation

Details using integrated synchronisation for multiple sensors by connecting Sync/Com-channels.

Installation Guide

Physical Connection and Parameter Setting

Covers sensor mounting, connector connection, and parameter adjustment.

Initial Start-up

Factory Default Settings

Lists the default settings of mic+ sensors upon factory delivery.

Sensor Operation Details

Maintenance and Dirt Effects

Explains sensor maintenance, impact of dirt, and cleaning recommendations.

Temperature Compensation

Notes internal temperature compensation and optimum working point after 30 minutes.

Switched Output Indicator

States a yellow LED D2 signals a connected switched output during normal operation.

Distance Measurement Display

Describes the LED-indicator displaying measured distance in mm or cm, with automatic scale switching.

Teach-in Mode and Hysteresis

Explains that hysteresis loops are reset to factory settings during Teach-in mode.

No Object Detection Display

Indicates that '--' is shown on the LED-indicator when no objects are in the detection zone.

Parameter Setting Timeout

Details that changes are stored and sensor returns to normal mode if no buttons are pressed for 20 seconds.

Key Lock and Factory Reset

Mentions options to lock the keypad and reset factory settings.

Parameter Display

Describes how tapping T1 shows 'PAr' and cycles through actual switched output settings.

Teach-in Procedure

Teach-in Switched Output

Guides through the process of teaching the switched output for different detection modes.

Add-on Menu Functions

Accessing and Navigating Add-on Menu

Explains how to start and navigate the Add-on menu using T1 and T2 buttons.

Function Parameters

Details various programmable parameters like display brightness, filters, hysteresis, and response time.

Multiplex Mode Addressing

Describes setting sensor addresses for multiplex mode and synchronisation.

Measurement Range and Calibration

Covers setting the measurement range and performing calibration with a plane reflector.

Detection Zone Sensitivity

Explains how to adjust detection zone sensitivity ('E01', 'E02', 'E03').

Key Lock and Factory Setting

TouchControl Activation/Deactivation

Explains how to activate or deactivate TouchControl using the T1 button.

Reset to Factory Setting

Details the procedure to reset the sensor to its factory default settings.

Technical Data

Sensor Pin Assignment

Illustrates pin assignments for 1 pnp and 1 npn switched output sensors.

Detection Zone Characteristics

Presents detection zone charts for different mic+ sensor models based on object type and distance.