EasyManuals Logo

Microtek NDT-2000 Assemble

Microtek NDT-2000
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
I49-005438 A
Assemble the Multi-Channel Film Feeder (MFF) with the Digitizer
Before using the Multi-channel Film Feeder (MFF) with your digitizer, you need to mount it onto the digitizer. Follow the
instructions and graphs belows to assemble the MFF correctly.
Securing the Back Support
After the Base Tray has been installed on the digitizer, please
follow the steps below to lock two Back Supports at the back
of the Base Tray.
To lock the rst Back Support:
1. Look for the side with a soft pad of the Back Support and
put it facing down towards the top of the digitizer.
2. Lean the other side with a groove of the Back Support on
the back of the Base Tray, making sure the bottom of the
groove on the Back Support match with the bottom of the
groove on the Base Tray
.
Accessories in the Box
Check for the major components listed here.
Installing the Base Tray
1) Look for two sets of the Feed Tray Holes at both ends of
the front-top of the digitizer.
2) Insert and push down both sides of the Base Tray into its
compartment holes, making sure the Base Tray snaps into
place.
Base Tray
Quick-lock Nuts
Multi-channel Film Tray
Back Supports
Film-rolling
Rack
Screw & Washer Sets
Feed Tray Holes
Base Tray
3. Insert one set of Screw & Washer through the bottom
groove of the Back Support; then, screw one Quick-lock
Nut on the set clockwise. Follow the step here to lock
the top Quick-lock Nut on the Base Tray and the Back
Support.
4. Follow the step 1 to 3 to secrue another Back Support on
the back of the Base Tray.
Screw &
Washer
Quick-lock Nut
Match up the bottom
groove of the Back
Support with the
bottom groove of the
Base Tray.
MFF Mask Kit

Other manuals for Microtek NDT-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microtek NDT-2000 and is the answer not in the manual?

Microtek NDT-2000 Specifications

Scanning Specifications IconScanning Specifications
resolution1200 dpi (21 μm)
optical density0.37D~ 4.5D
scanning area min2.5” x 2.5” (63.5 mm x 63.5 mm)
scanning area max14“ x 200” (355.6 mm x 5080 mm)
scanning speed 3.5D58 sec @ 300 dpi, 14” x 17” grayscale
scanning speed 4.0D110 sec @ 300 dpi, 14” x 17” grayscale
scanning speed 4.5D232 sec @ 300 dpi, 14” x 17” grayscale
Film Specifications IconFilm Specifications
film size min2.5” x 2.5” (63.5 mm x 63.5 mm)
film size max14“ x 200” (355.6 mm x 5080 mm)
film holder8.5” x 4.5”, 12” x 3 1/3”
Power IconPower
voltageAC 100V to 240V, 50/60 Hz
max current4.0A (Input)
power consumptionMax. 320 W
Operating Environment IconOperating Environment
operating temperature50° to 104°F (10° to 40°C)
operating relative humidity20% to 85%
storage temperature14° to 140°F (-10° to 60°C)
storage relative humidity20% to 95%
Weight and Dimensions IconWeight and Dimensions
dimensions12.9” x 18.7” x 8.8” (329 x 474 x 224 mm)
dimensions with input tray329 x 474 x 544 mm
dimensions with input and output tray586 x 474 x 934 mm
weight44.5 lbs. (20.2 kg)