36
stopped.
8.4.10.2 Orientation means after the original orientation action, the louver turn the middle position of
upper limit position and lower limit position.
8.4.10.3 Vane adjustment, pressing the control button on the remote controller to make the vertical
louver turn left and right. Each pressing, the louver will turn 6. If pressing the button during the
original orientation, the louver will only turn 6after the original orientation action stopped regardless
the pressing time. No action when the unit is stopped.
8.4.10.4 Horizontal swing means the louver can auto swing horizontally in the allowable range if
pressing the button on the remote controller. Pressing once, the louver starts movement, the second
pressing is to stop the moving.
If indoor fan stopped, the horizontal swing is invalid.
8.4.11 8
Heating (Control by remote control)
In heating operation, the preset temperature of the air conditioner can be as lower as 8, which keeps
the room temperature steady at 8 and prevents household things freezing when the house is
unoccupied for a long time in severe cold weather.
8.4.12 Ionizer/Plasma dust collector function (optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote
controller. When the unit is turned on, press the CLEAN AIR button to activate the function. Press it
again to stop the function. During the time when Ionizer being controlled by remote controller, Ionizer
will be turned off automatically, if indoor fan stops running due to malfunctions or anti-cold-wind. When
indoor fan restarts after malfunctions being eliminated and anti-cold-wind being released, Ionizer will
be available again.