Split Type Room Air Conditioner
For trouble free services please register with our Customer Care on 180030000011
or write to us at : mideacare@carriermidea.com
11D Series-Fixed Speed/Inverter
Question and Answer IconNeed help?

Do you have a question about the Midea 9000 Btu and is the answer not in the manual?

Summary

Safety Precautions

Safety Symbols and Warnings

Explains warning symbols and crucial safety alerts for operation and installation.

General Safety Precautions

Provides essential precautions for handling, cleaning, and operating the air conditioner safely.

Operating Instructions

Unit Components and Display

Details the parts of the indoor and outdoor units and their display indicators.

Special Functions

Describes optional features like Self Clean, Clean Air, and Anti-mildew functions.

Operating Modes and Temperatures

Outlines operating temperatures and manual operation procedures.

Airflow Direction Control

Explains how to adjust airflow direction and associated safety cautions.

Understanding Air Conditioner Operations

Covers operational modes like AUTO, SLEEP, DRYING, and tips for optimal performance.

Care and Maintenance

Cleaning Procedures

Provides instructions for cleaning the unit, filters, and air freshening filters.

Maintenance and Checks

Details long-term maintenance, pre-operation checks, and cautions.

Operation Tips

Normal Operation Events

Explains common operational events like mist, noise, smells, and mode changes.

Operational Scenarios and Advice

Covers specific scenarios like dripping water, heating, auto-restart, and external interference.

Troubleshooting Tips

Troubleshooting Guide

Lists common malfunctions, their causes, and recommended solutions.

E-Waste Management Guidelines

E-Waste Handling and Disposal

Provides guidelines for proper disposal and explains the e-waste symbol.

Hazardous Constituents and Dos;Donts

Discusses hazardous materials and lists recommended practices for e-waste.

Warranty Terms & Conditions

Warranty Coverage Details

Outlines the general unit and compressor warranty terms and conditions.

Warranty Limitations and Exclusions

Specifies conditions that void the warranty and limitations of coverage.

Warranty Card

Product Warranty Certificate

Contains sections for the Midea copy and customer copy of the warranty certificate.

Overview

This document is a user manual for the Midea 11D Series Fixed Speed/Inverter Split Type Room Air Conditioner. It provides comprehensive information on safety precautions, operating instructions, care and maintenance, troubleshooting tips, e-waste management guidelines, and warranty terms and conditions.

Function Description:

The Midea 11D Series air conditioner is designed to provide cooling, heating (on cooling & heating models), and dehumidifying functions for indoor spaces. It features various operating modes including AUTO, COOL, HEAT, DRY, and FAN ONLY. The unit incorporates special functions such as Refrigerant Leakage Detection, Louver Angle Memory Function (optional), SELF CLEAN function (optional), CLEAN AIR function (on some models), and Anti-mildew function (optional).

Refrigerant Leakage Detection: This feature alerts the user with an 'EC' display and flashing LED indication lamps on the outdoor unit if refrigerant leakage is detected, enhancing safety and system integrity.

Louver Angle Memory Function (Optional): The air conditioner can memorize the open angle of the horizontal louver within a safe range. If the set angle exceeds the safety boundary, it will revert to a standard angle. This function is temporarily overridden by pressing the turbo or manual control button, or by unplugging and re-plugging the machine. Users are advised not to set the horizontal louver angle too small to prevent condensed water from dripping.

SELF CLEAN Function (Optional): Activated after cooling operation, this function cleans the evaporator to maintain fresh air for subsequent operations. For cooling models, the unit runs in FAN ONLY mode at low speed for 30 minutes before turning off. For cooling & heating models, it follows a sequence of FAN ONLY (low speed), Heating (low speed), FAN ONLY, and then turns off. This function is available in COOL (AUTO COOL, FORCED COOL) and DRY modes. It is recommended to run the air conditioner in cooling mode for about 30 minutes before activating SELF CLEAN. Activating SELF CLEAN cancels all TIMER settings. Pressing the SELF CLEAN button again during operation will stop the unit.

CLEAN AIR Function (on some models): This function improves indoor air quality through an ionizer or Plasma Dust Collector (depending on the model). The ionizer generates anions for refreshing and healthy air circulation. The Plasma Dust Collector creates a high-voltage ionization zone, converting air into plasma and capturing dust, smoke, and pollen particles with an electrostatic filter.

Anti-mildew Function (Optional): When the unit is turned off in COOL, DRY, or AUTO (Cool) mode, it continues to operate for 7-10 minutes with soft wind. This helps dry condensed water inside the evaporator, preventing mildew growth. The air conditioner should not be restarted until it has completely turned off after the anti-mildew operation.

Important Technical Specifications:

The manual provides a table for model names and dimensions (Width, Height, Depth) in millimeters for various Btu capacities:

  • 9000 Btu: 680mm (W), 255mm (H), 180mm (D)
  • 12000 Btu: 770mm (W), 255mm (H), 188mm (D)
  • 18000 Btu: 905mm (W), 275mm (H), 198mm (D)
  • 24000 Btu: 1030mm (W), 315mm (H), 220mm (D)

Operating Temperature Ranges:

  • Room Temperature:
    • Cooling: 17℃~32℃ (62°F~90°F)
    • Heating: 0℃~30℃ (32°F~86°F)
    • Drying: 10°C~32°C (50°F~90°F)
  • Outdoor Temperature:
    • Cooling: 18℃~43℃ (64°F~109°F)
      • For low-temperature cooling systems: -7°C~43°C (20°F~109°F)
      • For special tropical models: 18°C~52°C (64°F~126°F)
    • Heating: -7℃~24℃ (20°F~76°F)
    • Drying: 18°C~52°C (64°F~126°F) (For special tropical models)

VLED Display Window:

  • ION indication lamp (optional): Lights up when Clean Air feature is activated.
  • RUN indication lamp: Illuminates when the air conditioner is in operation.
  • TIMER indication lamp: Lights up during Timer operation.
  • DEFROST indication lamp (cooling & heating models only): Lights up during automatic defrosting or warm air control in heating operation.

Usage Features:

  • Manual Operation: In case the remote controller is disabled or for maintenance, the unit can be operated manually. By lifting the front panel and pressing the manual button, the operation mode cycles through AUTO, COOL, OFF. The default setting temperature is 24°C/76°F. This is for testing purposes only; the remote controller should be used to restore normal operation.
  • Airflow Direction Control:
    • Vertical Airflow (Up-Down): Adjusted using the remote controller, the horizontal louver moves 6° per press or swings automatically.
    • Horizontal Airflow (Left-Right): Adjusted manually by moving the deflector rod. Users are warned not to insert fingers into the blower and suction panels due to high-speed fan danger.
  • Optimal Operation Tips:
    • Adjust airflow direction away from people.
    • Set temperature for maximum comfort, avoiding excessive levels.
    • Keep doors and windows closed in COOL or HEAT modes.
    • Use TIMER ON for scheduled operation.
    • Avoid placing objects near air inlets or outlets.
    • Clean the air filter periodically.
    • Do not operate with the horizontal louver in a closed position.
  • Sleep Operation: During cooling, heating, or AUTO operation, the unit automatically adjusts the temperature by 1°C/2°F per hour for the first 2 hours, then maintains it for 5 hours before switching off. This mode saves energy and enhances comfort.
  • Auto-restart Function: For units with this feature, after a power failure, the unit automatically restarts with all previous settings preserved. For units without, the OPERATION indicator flashes, and the ON/OFF button on the remote controller must be pressed to restart.

Maintenance Features:

  • Cleaning the Grille, Case, and Remote Controller: Turn off the system and disconnect power before cleaning. Wipe with a soft, dry cloth. Avoid bleach, abrasives, chemically treated cloths, benzine, thinner, polishing powder, or water hotter than 40°C/104°F to prevent damage or discoloration.
  • Cleaning the Air Filter: A clogged air filter reduces cooling efficiency. Clean the filter every two weeks.
    1. Lift the indoor unit panel until it clicks (use suspension bars for 24K Btu models).
    2. Hold the air filter handle, lift slightly, and pull downwards to remove.
    3. Clean the air filter with a vacuum cleaner or water, then dry it in a cool place.
  • Air Freshening Filter (on some models): Remove from its supporting frame. Clean at least once a month and replace every 4-5 months. Clean with a vacuum cleaner and dry in a cool place. Reinstall securely.
  • Long-term Idling Maintenance:
    1. Clean the indoor unit and filters.
    2. Operate the fan for about half a day to dry the unit's interior.
    3. Stop the air conditioner and disconnect power.
    4. Remove batteries from the remote controller.
    • The outdoor unit requires periodic maintenance by an authorized dealer or service provider.
  • Checks Before Operation:
    • Verify wiring is intact and connected.
    • Ensure indoor unit and filters are clean.
    • Confirm air filter is installed.
    • Check for blockages at air outlet or inlet, especially after prolonged non-use.

Safety Precautions:

The manual emphasizes critical safety precautions using "WARNING" and "CAUTION" symbols.

  • WARNING: Indicates possibility of death or serious injury. Examples include:
    • Properly connect power to avoid electric shock/fire.
    • Do not modify power cord or share outlets.
    • Ensure effective grounding.
    • Disconnect power if strange sounds, smell, or smoke occur.
    • Use correctly rated breaker/fuse.
    • Do not operate/stop unit by switching power on/off.
    • Do not operate with wet hands or in damp environments.
    • Do not allow water into electrical parts.
    • Do not drink drained water.
    • Do not use power cord near heating appliances or flammable materials.
    • Ventilate room if gas leakage from other appliances.
    • Do not damage or use unspecified power cord.
    • Do not direct airflow at room occupants.
    • Install circuit breaker and dedicated power circuit.
    • Do not open unit during operation.
    • Do not disassemble or modify unit.
  • CAUTION: Indicates possibility of injury or property damage. Examples include:
    • Avoid touching metal parts when removing air filter.
    • Switch off and turn off circuit breaker before cleaning.
    • Stop operation and close windows during storms/hurricanes.
    • Do not use strong detergents (wax, thinner) for cleaning.
    • Do not place heavy objects on power cord.
    • Do not clean with water.
    • Do not put thin rods into blower/suction panels.
    • Do not expose pets/plants to direct airflow.
    • Do not place obstacles around air-inlets or inside air-outlet.
    • Ensure outdoor unit bracket is undamaged.
    • Ventilate room well when used with stoves.
    • Do not use for special purposes (e.g., preserving precision devices, food, pets).
    • Turn off main power switch when not using for long periods.
    • Insert filters securely and clean every two weeks.
    • Use caution when unpacking/installing due to sharp edges.
    • If water enters the unit, turn off, disconnect power, and contact a qualified technician.
    • Do not operate with airflow directed downward in cooling/dehumidifying mode for long periods to prevent condensation.
    • Horizontal louver may not move for ~10 seconds after restart.
    • Do not set horizontal louver angle too small.
    • Do not move horizontal louver manually; if it goes out of sync, restart the unit.
    • Do not operate unit with horizontal louver in closed position.

E-Waste Management Guidelines:

The manual outlines responsibilities under the e-waste Management and Handling Rules, 2011. Consumers are urged to properly channelize e-waste for recycling and disposal, avoiding landfills. The symbol of a crossed-out wheeled bin indicates that Midea air-conditioners should not be disposed of in garbage bins or through scrap dealers.

Warranty Terms & Conditions:

  • Unit Warranty: 12 months from invoice date, covering defects in materials and workmanship under normal use and specified voltage conditions. Repair or replacement of defective parts (compressor, condenser, evaporator) is free of charge. Plastic parts, fuses, air filters, refrigerants, and other expendable items are excluded.
  • Five-Year Compressor Warranty: Extends for four years after the unit warranty expires, covering compressor defects under normal use and specified voltage conditions. Repair or replacement of defective compressor parts is free, but transportation charges must be prepaid. Expendable items like refrigerant gas, oil, dryer, and strainer are excluded and chargeable.
  • Conditions: Warranty is valid only if the fault is duly intimated to the Company or authorized dealer, and the unit is in the purchaser's possession and use. Warranty period is fixed regardless of usage or relocation. It is void if serviced, repaired, installed, de-installed, re-installed, or attended to by unauthorized personnel. Parts replaced are warranted for the remaining original warranty period. Outstation service calls incur travel and incidental expenses borne by the purchaser.
  • Exclusions: Loss of refrigerant due to sabotage, improper handling, accident, fire, flood, earthquake, acts of God, or corrosive action on pipes/fittings. Changes in unit location without prior written notice to authorized dealer. Damage during transit. Company is not liable for specific repair timelines. Company has discretion over repair location and personnel. Company is not liable for direct, indirect, incidental, or consequential loss/damage.
  • Specific Warranty Limitations: No warranty for damage caused by accident, mishandling, tampering, negligent instruction following, power surges/dips, improper electrical circuits, unauthorized repairs, altered/defaced serial numbers, unauthorized removal/reinstallation, defective condenser/evaporator due to muddy sewages/toxic gases, or damage from abnormally corrosive alkaline/acidic atmospheres.
  • No employee/authorized dealer can vary warranty terms.
  • Warranty is issued in Gurgaon, Haryana, and Courts at Gurgaon have exclusive jurisdiction.

Midea 9000 Btu Specifications

General IconGeneral
BrandMidea
Model9000 Btu
CategoryAir Conditioner
LanguageEnglish

Related product manuals