8.4 Operation Modes and Functions 
8.4.1 Fan mode 
(1) Outdoor fan and compressor stop. 
(2) Temperature setting function is disabled, 
and no setting temperature is displayed. 
(3) Indoor fan can be set to 
high/med/low/auto. 
(4) The louver operates same as in cooling 
mode. 
(5) Auto fan: 
 
 
8.4.2.2 Indoor fan running rules 
In cooling mode, indoor fan runs all the time 
and the speed can be selected as high, 
medium, low and auto. 
The indoor fan is controlled as below: 
 
---TP3<T3< TP3+5, the compressor frequency 
will decrease to the lower level until to F1 and 
then  runs  at  F1.If  TP3-3<T3<  TP3,  the 
compressor  will  keep  running  at  the  current 
frequency. 
---T3< TP3-3, the compressor will not limit the 
frequency and resume to the former frequency. 
---T3>  TP3+5  for  5  seconds,  the  compressor 
will stop until T3< TP3-3. 
 
8.4.2.4 Evaporator temperature protection 
---T2<0℃, the compressor will stop and restart 
when T2≥5℃. 
---0℃≤T2<4℃,  the  compressor  frequency  will 
be limited and decreased to the lower level until