M thermal Split
202004                                                                                                                                                                                                                      45
Figure 4-2.6: MHA-V12(14,16)W/D2N8-B outdoor unit inverter module
    1            2          3                          4 
 
 
 
 
 
 
 
 
 
 
 
 
5
 
 
6
 
7
 
 
10                9                                                                                                  11      8     
 
Table 4-2.6: MHA-V12(14,16)W/D2N8-B outdoor unit inverter module 
Label in 
Figure 4-2.6 
Code  Content 
1  U 
Compressor connection port U 
2  V 
Compressor connection port V 
3  W 
Compressor connection port W 
4  CN19 
Port for fan 
5  CN20 
Output port for +12V/9V 
6  CN32 
Port for communication with main PCB for filter board 
7  CN23 
Port for high pressure switch 
8  CN6 
Reserved 
9  CN501 
Input port L for rectifier bridge 
10  CN502 
Input port N for rectifier bridge 
11  IC14 
EEPROM 
 
Midea CAC