Installation
 Page 121 
192mm (7.55in)
232mm (9.15in)
128mm (5.05in)
43mm (1.7in)
297mm (11.7in)
Left rear wall 
hole 65mm  (2.5in)
Right rear wall 
hole 65mm (2.5in)
Indoor unit outline
802mm (31.6in)
43mm (1.7in)
12K Model
144mm (5.65in)
58mm (2.3in)
319mm (12.55in)
57mm (2.25in)
Right rear wall 
hole 65mm (2.5in)
965mm (38in)
138mm (5.45in)
34mm (1.35in)
Indoor unit outline
517.4mm (20.37in)
18K Model
219mm (8.6in)
553mm (21.77in)
300mm (11.8in)
Left rear wall 
hole 65mm (2.5in)
Right rear wall 
hole 65mm (2.5in)
1080mm (42.5in)
53.5mm
(2.1in)
47mm (1.85in)
76mm(3in)
53.5mm (2.1in)
47mm (1.85in)
148.7mm
(5.85in)
151mm (5.95in)
174.3mm (6.85in)
Indoor unit outline
24K Model
For All Easy series:
302mm(11.9in)
805mm(31.7in)
406.4mm(16in)
249mm(9.8in)
153mm(6in)102mm(4in)
pipe hole 
φ
65mm
2.56 in)
pipe hole 
φ
65mm
(2.56 in)
Indoor unit outline
54mm(2.1in)
9K/12K Model
964mm(37.9in)
482mm(19in)
325mm(12.8in)
pipe hole 
φ
65mm
(2.56 in)
pipe hole 
φ
65mm
(2.56 in)
132mm
(5.20in)
219mm(8.62in)
262mm(10.31in)439mm(17.28in)
18K Model
1106mm(43.5in)
599mm(23.6in)
342mm(13.5in)
pipe hole 
φ
65mm
2.56 in)
pipe hole 
φ
65mm
(2.56 in)
Indoor unit outline
174mm
(6.85in)
320mm(12.60in)
130mm
(5.12in)
558mm(21.97in)
24K Model
• Note for concrete or brick walls:
If the wall is made of brick, concrete, or similar material, 
drill 5mm-diameter (0.2in-diameter) holes in the wall 
and insert the sleeve anchors provided. Then secure the 
mounting plate to the wall by tightening the screws 
directly into the clip anchors.
3.3  Drill wall hole for connective piping
You must drill a hole in the wall for refrigerant piping, the 
drainage pipe, and the signal cable that will connect the 
indoor and outdoor units. 
1. Determine the location of the wall hole based on the 
position of the mounting plate. Refer to Mounting Plate 
Dimensions on the next page to help you determine the 
optimal position. The wall hole should have a 65mm 
(2.5in) diameter at least, and at a slightly lower angle to 
facilitate drainage.
2. Using a 65mm (2.5in) or 90mm(3.54in) (depending on 
models )core drill, drill a hole in the wall. Make sure that 
the hole is drilled at a slight downward angle, so that the 
outdoor end of the hole is lower than the indoor end by 
about 5mm to 7mm (0.2-0.27in). This will ensure proper 
water drainage.
3. Place the protective wall cuff in the hole. This protects 
the edges of the hole and will help seal it when you finish 
the installation process.
NOTE: When drilling the wall hole, make sure to avoid 
wires, plumbing, and other sensitive components.
Wall
Indoor Outdoor
mm7-5