DM16-01.01.11-01en   Service manual 
Multi DC inverter R410A. Outdoor unit    5 
3. Specification 
Outdoor Model  M2OE-14HFN1-Q M2OF-18HFN1-Q
Indoor unit combination  Single Double  Single  Double
Power supply  V-ph-Hz  220-240V- 50Hz, 1Ph  220-240V- 50Hz, 1Ph 
Cooling 
Capacity   Btu/h 
7000-14000  14000 7000-18000 18000 
Input             W  660-1250  1200 650-1600 1643 
Rated current     A  2.9-5.4  5,2 2.8-7.0 7,1 
EER  W/W  /  3,30   /  3,21 
Heating 
Capacity  Btu/h 
8000-15000  15000 7000-19000 19000 
Input             W  620-1280  1160 542-1596 1543 
Rated current     A  2.7-5.6  5 2.3-6.9 6,7 
COP  W/W  /  3,80   /  3,61 
Max. input consumption          W  2000 2600 
Max. input current   A  11 14 
Compressor 
Model     
ASN108D22UEZ ASM135D23UFZ 
Type      ROTARY ROTARY 
Brand      GMCC GMCC 
Capacity       Btu/h  10987 13836 
Input            W  825 1035 
Rated current(RLA)    A  5,8 7.32 
Locked rotor Amp(LRA)        A  / ---- 
Thermal protector position    / ---- 
Capacitor   μF  / ---- 
Refrigerant oil   ml  ESTER OIL VG74  370  ESTER OIL VG74/450 
Outdoor fan 
motor 
New Model      ZKFN-40-8-1L ZKFN-40-8-1L 
Model         
Qty      40(Output) 40(Output) 
Output W / / 
Capacitor  μF  / / 
Speed(Hi/Med/Lo) r/min 810 810 
Outdoor coil 
Number of rows   
1 2 
Tube pitch(a)* row pitch(b)    mm  21x13.37 25.4x22 
Fin spacing  mm  1.2 1.4 
Fin type      Hydrophilic aluminium  Hydrophilic aluminium 
Tube outside dia.and type    mm  Φ7,innergroove tube  Φ9.52,innergroove tube 
Coil length * height * width  mm  870x504x13.37 860x508x44 
Number of circuits    2 4 
Outdoor air flow              m3/h  2100 2100 
Outdoor  sound pressure level  dB(A)  54 56.5 
Throttle type    Capillary+EXV Capillary+EXV 
Outdoor unit 
Dimension(WxDxH) mm 
800x333x554 800x333x554 
Packing(WxDxH) mm 920x390x615 920x390x615 
Net/Gross weight      kg  30.5/33.5 36/39 
Refrigerant   
Type     
R410A R410A 
GWP   2088 2088 
Charged quantity  Kg  1.25 1.7 
Design pressure  MPa  4.2/1.5 4.2/1.5 
Refrigerant 
piping 
Liquid side/ Gas side      mm(inch) 
2 x Φ6.35/Φ9.52(1/4"/3/8") 2 x Φ6.35/Φ9.52(1/4"/3/8") 
Max. length for all rooms  m  30 30 
Max. length for one indoor unit  m  20 20 
Max. height difference 
between indoor and 
outdoor unit   
OU higher 
than IU 
m 
10 10 
OU lower 
than IU 
m 
15 15 
Max. height difference between indoor 
units  
m 
10 10 
Ambient 
temperature 
Cooling 
Ԩ 
-15-50 -15-50 
Heating 
Ԩ 
-15-24 -15-24 
1.The above design and specifications are subject to change without prior notice for product improvement. 
2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms.