EasyManua.ls Logo

Midea M5OE-42HFN1-Q - Page 6

Midea M5OE-42HFN1-Q
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service manual DM16-01.01.11-01en
6 Multi DC inverter R410A. Outdoor unit
Outdoor Model M3OE-21HFN1-Q M3OE-27HFN1-Q
Indoor unit combination Single Double Three Single Double Three
Power supply V-ph-Hz 220-240V- 50Hz, 1Ph 220-240V- 50Hz, 1Ph
Cooling
Capacity Btu/h 7000-12000 14000-18000 21000 7000-18000 14000-26000 27000
Input W 1000-1300 1500-1780 1917 750-1700 1400-2350 2465
Rated current A 4.4-5.7 6.5-7.7 8,3 3.3-7.4 6.1-10.2 10,7
EER W/W / / 3,21 / / 3,21
Heating
Capacity Btu/h 8000-14000 17000-20000 22500 8000-20000 16000-28000 28000
Input W 800-1200 1400-1630 1826 720-1750 1520-2174 2273
Rated current A 3.5-5.3 6.1-7.1 7,9 3.2-7.7 6.6-9.5 9,8
COP W/W / / 3,61 / / 3,61
Max. input consumption W 2800 3300
Max. input current A 15 16
Compressor
Model ASM135D23UFZ ATF235D22UMT
Type ROTARY ROTARY
Brand GMCC GMCC
Capacity Btu/h 13836 24345
Input W 1035 1970
Rated current(RLA) A 7,32 6,95
Locked rotor Amp(LRA) A ----- -----
Thermal protector position ----- EXTERNAL
Capacitor μF ----- -----
Refrigerant oil ml ESTER OIL VG74/450 POE(VG74)/670
Outdoor fan
motor
New Model ZKFN-50-8-2 ZKFN-50-8-2
Model
Qty 1 1
Output W 50 50
Capacitor μF - - - -
Speed(Hi/Med/Lo) r/min 750 750
Outdoor coil
Number of rows 2 2
Tube pitch(a)* row pitch(b) mm 21x13.37 25.4x22
Fin spacing mm 1.2 1.4
Fin type Hydrophilic aluminium Hydrophilic aluminium
Tube outside dia.and type mm Φ7, innergroove tube Φ9.52,innergroove tube
Coil length * height * width mm 730x651x26.74 730x660x44
Number of circuits 6 4
Outdoor air flow m3/h 2700 3500
Outdoor sound pressure level dB(A) 57,5 59.5
Throttle type Capillary+EXV Capillary+EXV
Outdoor unit
Dimension(WxDxH) mm 845x363x702 845x363x702
Packing(WxDxH) mm 965x395x755 965x395x755
Net/Gross weight kg 47/50.2 52.7/56.1
Refrigerant
Type R410A R410A
GWP 2088 2088
Charged quantity Kg 2,1 2,1
Design pressure MPa 4.2/1.5 4.2/1.5
Refrigerant
piping
Liquid side/ Gas side mm(inch) 3 x Φ6.35/Φ9.52(1/4"/3/8") 3 x Φ6.35/Φ9.52(1/4"/3/8")
Max. length for all rooms m 45 45
Max. length for one indoor unit m 25 25
Max. height
difference
between indoor
and outdoor unit
OU
higher
than IU
m 10 10
OU lower
than IU
m 15 15
Max. height difference between
indoor units
m 10 10
Ambient
temperature
Cooling -15-50 -15-50
Heating -15-24 -15-24
1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms.