MFAU-09HRFN1-M(C), MFAU-12HRFN1-M(C)
A. Micro-switch SW1 is for selection of auto-restart function.
Range: Active, inactive.
B. Take off the panel, you can see the switch SW101 which is used for selecting both air outlets or upper
air outlet only.
C.Micro-switch SW102 is for selection of temperature compensation in heating mode. This helps to
reduce the real temperature difference between ceiling and floor so that the unit could run properly. If the
unit is on-floor installed, 0 should be chosen.
Range: E function (reserved for special customizing) /0
o
C, 2
o
C, 4
o
C, -2
o
C
D. Micro-switch SW103 is for selection of indoor FAN ACTION if room temperature reaches the setpoint
and the compressor stops.
Range: OFF (in 127s), Low Speed, Setting Speed, Termal (runs for 1 minute ever 4-minute stop).