X X
Outdoor temperature sensor(coil
sensor T3 or ambient temperature
sensor T4) malfunction or
Outdoor unit EEPROM parameter
error
E6 E0,E4
X Outdoor fan speed malfunction E7 E8
X Indoor fan speed malfunction F5 ——
X
Over-voltage or under-voltage
protection
P0 E5
X Current overload protection P2 P3
X X Compressor drive malfunction P4 ——
X
Indoor units mode conflict P5 ——
flash at 2.5Hz, light, X extinguished, , flash at 0.5Hz
For Old Vertu/Luna Series
De-
Timer
Auto
Operatio
Failure
Display
Indoor unit EEPROM parameter error E0
Communication malfunction between indoor
and outdoor units error
E1
Zero-crossing signal detection error E2
Indoor fan speed malfunction E3
X
X
Outdoor temperature sensor(coil sensor T3
or ambient temperature sensor T4)
malfunction or Outdoor unit EEPROM
E5
Indoor room temperature sensor(room sensor
T1 or coil sensor T2) malfunction
E6
Outdoor fan speed malfunction E7
X
X
Inverter module (IPM) malfunction P0
X
Over-voltage or under-voltage protection P1
X
X
Compressor top high temperature protection
(OLP)
P2
X
Low ambient temperature cut off in heating P3
X
Compressor drive malfunction P4
X
Indoor units mode conflict P5
For All new models(New Wall mounted(Hi-Wall) series, New Duct/Cassette/Console/Floor
Ceiling):
Operation
lamp
Timer
lamp
Display LED STATUS
ODU
Error
1 time
X E0 Indoor unit EEPROM parameter error
——