89
8.4.2.13 P6 (Inverter module (IPM) malfunction) diagnosis and solution.
Error Code
P6
Malfunction conditions
When the voltage signal that IPM send to compressor drive
chip is abnormal, the display LED will show “P6” and AC will
turn off.
Potential causes
Wiring mistake
IPM malfunction
Faulty outdoor fan assembly
Compressor malfunction
Faulty outdoor PCB