Loading...
Air-cooled modular chiller unit 50Hz MCAC-ATSM-2011-12
56
8 Electric Characteristics
Model
Outdoor Unit Power Supply Compressor OFM
Hz Voltage Min. Max. TOCA MFA LRA RLA KW FLA
MGB-F25W/RN1 50 380-415 342 456 21.3 36 74(×2) 9.1(×2) 0.67 3.1
MGB-D25W/RN1 50 380-415 342 456 21.3 36 74(×2) 9.1(×2) 0.67 3.1
MGB-F30W/RN1 50 380-415 342 456
22.6 36 74(×2) 9.1(×2) 0.67 3.1
MGB-D30W/RN1 50 380-415 342 456
22.6 36 74(×2) 9.1(×2) 0.67 3.1
MGCSL-F30W/RN1 50 380-415 342 456 25.3 25 74(×2) 11.8(×2) 0.55 4
MGCSL-D30W/RN1 50 380-415 342 456 25.3 25 74(×2) 11.8(×2) 0.55 4
MGB-F55W/RN1 50 380-400 342 440
49.8 100 110(×2) 17.6 2) 0.65(×2) 3.0(×2)
MGB-F60W/RN1 50 380-400 342 440
51.7 100 110(×2) 17.6(×2) 0.65(×2) 3.0(×2)
MGB-F65W/RN1 50 380-400 342 440 54.5 100 110(×2) 17.6 2) 0.65(×2) 3.0(×2)
MGB-D65W/RN1 50 380-415 342 456
52 70 118/74/82.4 17.8/9.1/9.8 0.55(×2) 4.5(×2)
MGB-F130W/RN1 50 380-400 342 440
130 200 110(×4) 17.6 (×4) 0.88(×4) 4.0(×4)
MGB-F185W/RN1 50 380-400 342 440 160 180 110(×6) 17.6 6) 0.88(×6) 4.0(×6)
MGBT-F250W/RN1 50
380-400
342 440 191 280 177(×8) 20.8(×8) 5.6(×8) 14.4(×8)
Remark:
TOCA: Total Over-current Amps. (A)
MFA: Max. Fuse Amps. (A)
LRA: Locked Rotor Amps. (A)
RLA: Rated Locked Amps. (A)
OFM: Outdoor Fan Motor.
KW: Rated Motor Input (KW)
FLA: Full Load Amps.