M thermal Mono
68 200204
Midea M thermal Mono Service Manual
4.12 H6, HH Troubleshooting
Digital display output
Description
H6 indicates a DC fan error.
HH indicates that H6 protection has occurred 10 times in 2 hours. When an HH error occurs, a manual system restart
is required before the system can resume operation. The cause of an HH error should be addressed promptly in order
to avoid system damage.
M thermal Mono stops running.
Error code is displayed on refrigerant system main control board for refrigerant system and user interface.
Possible causes
Power or communication wires not connected properly.
High wind speed.
Fan motor blocked or has failed.
Power supply abnormal.
PFC module damaged.
IPM module damaged.
Main PCB damaged.