M thermal Mono         
50    200204 
Midea M thermal Mono Service Manual 
Table continued on next page … 
Table 4-3.1: Error code table (continued) 
User  interface and  refrigerant  system 
main PCB 
Zone  2  water  outlet  temperature  sensor 
error 
User  interface  and  hydronic  system 
main PCB 
Water  side  heat  exchanger  water  outlet 
temperature sensor error 
User  interface  and  hydronic  system 
main PCB 
Refrigerant system EEPROM error 
User  interface and  refrigerant  system 
main PCB 
User  interface and  refrigerant  system 
main PCB 
User  interface and  refrigerant  system 
main PCB 
Compressor current protection 
User  interface and  refrigerant  system 
main PCB 
Discharge temperature protection 
User  interface and  refrigerant  system 
main PCB 
High temperature difference between water 
side  heat  exchanger  water  inlet  and  water 
outlet temperatures protection 
User  interface  and  hydronic  system 
main PCB 
Inverter module protection 
Displayed  on  user  interface 
when  any  of  L0,  L1,  L2,  L4, 
L5, L7, L8 or L9 occur 
Inverter module protection 
Refrigerant system main PCB 
DC bus low voltage protection 
Refrigerant system main PCB 
DC bus high voltage protection 
Refrigerant system main PCB 
Refrigerant system main PCB 
Refrigerant system main PCB 
Refrigerant system main PCB 
Compressor frequency variation greater than 
15Hz within one second protection 
Refrigerant system main PCB 
Actual  compressor  frequency  differs  from 
target  frequency  by  more  than  15Hz 
protection 
Refrigerant system main PCB 
Water  side  heat  exchanger  anti-freeze 
protection 
User  interface  and  hydronic  system 
main PCB 
High  temperature  protection  of  refrigerant 
outlet  temperature  of  condenser  in  cooling 
mode 
User  interface and  refrigerant  system 
main PCB 
Water side heat exchanger inlet temperature 
is higher than outlet temperature in heating 
mode   
user  interface  and  hydronic  system 
main PCB 
Notes: 
1.  Sensor  names  in  this  service  manual  referring  to  refrigerant  flow  is  named  according  refrigerant  flow  during  cooling  operation  refer  to  Part  2,  3 
“Refrigerant Flow Diagrams”. 
2.  When the error code appears, the error code corresponding to the error code can be obtained through the H1H2 port by using the host computer to 
query the wired controller register.