M thermal Mono
202004 101
Procedure
bH
Power supply problem. After 5
minutes of power-off interval,
power on again and observe
whether it can be recovered.
Yes
Increase the power voltage to the
required range.
No
PED
1
board broken.
Yes
Replace PED PCB and power on again.
No
IPM module broken.
Yes
Replace IPM module and power on again.
Notes:
1. PED is port CN22 on the hydronic box main PCB (labeled 11 in Figure 4-2.7: MHA-V12(14,16)W/D2RN8-B outdoor unit inverter module ).