M thermal Mono
202004 105
4.25 PP Troubleshooting
Digital display output
Description
Water side heat exchanger inlet temperature is higher than outlet temperature in heating mode.
M thermal Mono stops running.
Error code is displayed on hydronic system main control board for refrigerant system and user interface.
If PP error occurs 3 times then Hb will appear.
Possible causes
Temperature sensor not connected properly or has malfunctioned.
4-way valve is blocked or damaged.
Hydronic system main PCB damaged.