EasyManua.ls Logo

Midea MHC-V4W/D2N8-B

Midea MHC-V4W/D2N8-B
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M thermal Mono
202004 107
4.26 HE Troubleshooting
Digital display output
Description
Communication error between main control board of hydronic module and Ta/room thermostat transfer PCB
M thermal Mono stops running.
Error code is displayed on hydronic system main PCB, outdoor unit main PCB and user interface.
Possible causes
Temperature collecting plate(Optional) connection wire is not connected.
Temperature collecting plate(Optional) is damaged.
Procedure
HE
Temperature collecting plate
connection wire is not connected.
Yes
Check the connection line and joint.
No
Temperature collecting plate is
damaged.
Yes
Replace temperature collecting plate