7.4.7 Auto-Restart function 
The  indoor  unit  is  equipped  with  auto-restart 
function,  which  is  carried  out  through  an 
auto-restart module. In case of a sudden power 
failure,  the  module  memorizes  the  setting 
conditions before the power failure. The unit will 
resume  the  previous  operation  setting  (not 
including swing  function) automatically  after 3 
minutes when power returns. 
If the memorization condition is forced cooling 
mode, the unit will run in cooling mode for 30 
minutes and turn to auto mode as 24℃  setting 
temp. 
If AC is off before power off and AC is required 
to  start  up  now,  the  compressor  will  have  1 
minute delay when power on. Other conditions, 
the compressor will have 3 minutes delay when 
restarts. 
 
 
7.4.8    8℃  Heating(optional) 
When the compressor is running, the indoor fan 
motor will run without anti-cold air function. 
When  the  compressor  is  off,  the  indoor  fan 
motor is off .