Blanc On-off DM16-01.01.07en
56 Service manual
11.2.7 Refrigerant Leakage Detection diagnosis and solution(EC)
Error Code
EC
Malfunction decision
conditions
Define the evaporator coil temp.T2 of the compressor just starts
running as Tcool.
In the beginning 5 minutes after the compressor starts up, if T2
Tcool2 does not keep continuous 4 seconds and this
situation happens 3 times, the display area will show “EC” and
AC will turn off.
Supposed causes T2 sensor faulty
Indoor PCB faulty
System problems, such as leakage or blocking.
Trouble shooting: