MCAC-UTSM-2008-11 Capacity Tables
Indoor Units 73
MUB-36HRN1 (3 phase)
Cooling
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 10.82 10.29 9.77 9.35
SC 8.00 7.92 7.81 7.85
Input 3.11 3.38 3.53 3.64
24/17ºC DB/WB
TC 11.13 10.61 10.08 9.45
SC 8.35 8.27 8.16 7.94
Input 3.30 3.53 3.68 3.86
27/19ºC DB/WB
TC 11.34 10.82
10.50
9.77
SC 8.39 8.33 8.19 8.01
Input 3.38 3.56
3.75
3.94
32/23ºC DB/WB
TC 11.55 11.13 10.92 10.08
SC 9.82 9.68 9.61 9.37
Input 3.53 3.68 3.94 4.09
Heating
Heating Outdoor conditions
Indoor Conditions (DB) (kW) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB
15ºC
TC 15.60 12.60 10.32 9.36
Input 4.00 3.44 2.96 2.78
20ºC
TC 15.12 12.00 9.72 9.12
Input 4.37 3.70 3.26 3.00
27ºC
TC 14.16 11.28 9.12 8.88
Input 4.63 4.00 3.52 3.26
Remark:
TC : Total capacity ; kW
SC: Sensible heat capacity ; kW
Input: Input power ; kW