MIDEA LCAC
50Hz R410A DC Inverter
Service Manual
2012

Table of Contents

Questions and Answers

  • R
    Ronald CaseyAug 13, 2025
    What to do if my Midea Inverter shows outdoor unit over-current protection?
    • S
      Stephanie PayneAug 13, 2025
      If the Midea Inverter's outdoor unit is experiencing over-current protection issues, it is recommended to inspect the unit for any electrical faults and rectify them.
  • P
    Paul SkinnerAug 17, 2025
    What to do if Midea MOU-48HDN1 Inverter displays IPM module protection?
    • U
      underwoodtimAug 17, 2025
      If your Midea Inverter is showing signs of IPM module protection activation, check the IPM module and reset or replace it if necessary.
  • S
    Shannon WilliamsAug 21, 2025
    What to do if my Midea MOU-48HDN1 Inverter shows a full-water malfunction?
    • H
      hfarmerAug 21, 2025
      To address a full-water malfunction in your Midea Inverter, empty the water tank and ensure that the drainage system is functioning correctly.
  • S
    Stephanie SmithAug 25, 2025
    How to fix communication malfunction in Midea Inverter?
    • S
      Susan CobbAug 26, 2025
      If you encounter a communication malfunction between the indoor and outdoor units of your Midea Inverter, check the communication lines to ensure they are securely connected.
  • C
    Christopher AlvarezAug 28, 2025
    What to do if Midea Inverter displays outdoor unit voltage protection?
    • R
      Richard OrtizAug 28, 2025
      If your Midea Inverter's outdoor unit is experiencing voltage protection issues, verify the voltage supply to the outdoor unit.
  • R
    Rebecca PatrickSep 1, 2025
    How to fix open or short circuit of T3 or T4 temperature sensor in Midea MOU-48HDN1 Inverter?
    • P
      Paula DelacruzSep 1, 2025
      To resolve an open or short circuit in the T3 or T4 temperature sensor of your Midea Inverter, inspect the sensor and replace it as required.
  • L
    Lisa KaneSep 5, 2025
    How to fix open or short circuit of T1 temperature sensor in Midea Inverter?
    • A
      Alexandria MurphySep 5, 2025
      To fix an open or short circuit of the T1 temperature sensor in your Midea Inverter, inspect the T1 temperature sensor and replace it if necessary.
  • A
    Amanda JonesSep 9, 2025
    How to fix open or short circuit of T2 temperature sensor in Midea Inverter?
    • E
      Erik SullivanSep 9, 2025
      To fix an open or short circuit of the T2 temperature sensor in your Midea Inverter, inspect the T2 temperature sensor and replace it if necessary.

Summary

Midea LCAC General Information

Midea LCAC Unit Model Identification

Lists Midea LCAC indoor/outdoor unit models and their compatible indoor units.

Midea LCAC Unit Visuals

Shows visual representations of different indoor and outdoor unit types.

Midea LCAC Unit Model Number Explanation

Explains the meaning of characters in model names for units.

Midea LCAC Unit Key Features and Benefits

Highlights key characteristics and advantages of the product series.

Midea LCAC Indoor Units

Midea Compact Four-Way Cassette Unit Specs

Details features, dimensions, and specifications for compact cassette units.

Midea Standard Four-Way Cassette Unit Specs

Covers features, dimensions, and specifications for standard four-way cassette units.

Midea Duct Type Indoor Unit Specs

Provides information on duct type indoor units, including features and specs.

Midea Ceiling and Floor Unit Specs

Details specifications and features for ceiling and floor mounted indoor units.

Midea Console Type Indoor Unit Specs

Covers features, dimensions, and operation of console type indoor units.

Midea LCAC Outdoor Units

Midea Outdoor Unit Physical Dimensions

Provides physical dimensions for various outdoor unit models.

Midea Outdoor Unit Installation Clearance

Specifies required clearance for outdoor unit installation and maintenance.

Midea Outdoor Unit Refrigerant Piping

Illustrates refrigerant piping configurations for different outdoor units.

Midea Outdoor Unit Electrical Wiring

Shows electrical wiring schematics for outdoor unit components.

Midea Outdoor Unit Electrical Specifications

Lists electrical specifications like voltage, current, and fuse ratings.

Midea Outdoor Unit Operating Temperature and Humidity

Defines the operational temperature and humidity ranges for the units.

Midea Outdoor Unit Noise Levels

Presents noise level data for outdoor units under different operating modes.

Midea Outdoor Unit Diagnostic Codes

Explains diagnostic codes and how to check unit status via PCB switches.

Midea Outdoor Unit Troubleshooting Guide

Provides guidance for diagnosing and resolving common outdoor unit malfunctions.

Midea LCAC Installation Procedures

Midea Unit Installation Safety Precautions

Outlines important safety and procedural steps before installing the unit.

Midea Unit Refrigerant System Vacuum and Leak Test

Details procedures for system evacuation and leak detection.

Midea Unit Refrigerant Charging Guide

Explains how to calculate and add refrigerant based on pipe length.

Midea Unit Drainpipe Installation and Testing

Covers drainpipe installation, gradient, and testing procedures.

Midea Unit Pipe Insulation Requirements

Specifies materials and methods for pipe insulation.

Midea Unit Installation Wiring Diagrams

Directs users to wiring diagrams for proper electrical connections.

Midea Unit Post-Installation Testing Procedures

Guides through the final checks and startup procedures after installation.

Midea LCAC Control Systems

Midea Wireless Remote Controller Operation

Explains the functions and operation of the wireless remote controller.

Midea MOU-48HDN1 Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity48000 BTU/h
Outdoor Unit Dimensions (HxWxD)340 mm
Operating Temperature (Cooling)18°C to 43°C
Operating Temperature (Heating)-15°C to 24°C