Operation
AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut,it will restart with the previous function 
setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to 
protect the unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
Adjust the air flow direction manually:
-The louver can be set to the desired position manually. 
-Do not place any heavy objects or other loads on the louver, doing so will cause damage to 
 the unit.
-Ensure the louver is fully opened under heating operation.
-Keep the louver fully opened during operation.
 
Water drainage
-During dehumidifying modes, remove the drain plug from the back of the unit, install the drain 
 connector(5/8" universal female mender) with 3/4" hose(locally purchased). For the models 
 without drain connector, just attach the drain hose to the hole. Place the open end of the hose 
 directly over the drain area in your basement floor.
Remove the 
drain plug
Continuous 
drain hose
-When the water level of the bottom tray 
 reaches a predetermined level, the unit beeps 8 times, the 
digital display area shows "P1" . At this time the air 
conditioning/dehumidification process will immediately stop. 
However, the fan motor will continue to operate(this is normal). 
Carefully move the unit to a drain location, remove the bottom 
drain plug and let the water drain away. Reinstall the bottom 
drain plug and restart the machine until the "P1" symbol 
disappears. If the error repeats, call for service.
Bottom drain 
plug
NOTE:When the continuous drain hose is not used,  ensure that the drain plug and 
knob are installed firmly to prevent leakage.
NOTE: Be sure to reinstall the bottom drain plug firmly to 
            prevent leakage before using the unit.
 13