EasyManua.ls Logo

Midea MS9A-05CR-QD0

Midea MS9A-05CR-QD0
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
8.4.3.4 Defrosting mode
For MS9A-21HR-QB6W and MA9A-24HR-QB4W models:
Condition of defrosting:
AC will enter defrosting mode if any of the following items is satisfied.
(1) When T3TC1, if the compressor keeps running over 45 minutes and T3TC3 for 3
minutes.
(2) After the last defrosting, the time that the outdoor fan is off but the compressor is on in high T2
protection cumulates up to 90 minutes.
Condition of defrosting stop:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.
(1)T3 rises to be higher than TC2.
(2)The machine has run for 10 minutes in defrosting.
Defrosting action
For other models:
Condition of defrosting:
AC will enter defrosting mode if any of the following items is satisfied.
(1) Both A and B are satisfied
A: The compressor keeps running for 40 minutes.
B: The evaporator coil temp.T2-Indoor room temp.T1 meets the below table.
T2T1
High speed
TH
DEFROST
Medium speed
TM
DEFROST