Display LED STATUS
E0 EEPROM parameter error
E1 Indoor / outdoor units communication protection
E2 Zero-crossing signal error
E3 Indoor fan speed out of control
E5 Open or short circuit of outdoor ambient or condenser temperature sensor
E6 Open or short circuit of indoor room or evaporator temperature sensor
P0 Inverter module (IGBT) over-strong current protection
P1 Over voltage or too low voltage protection
P2 Temperature protection of compressor top.
P4 Inverter compressor drive error