12
Drill wall hole
12
When drilling the wall hole, make sure to avoid wires, plumbing, and other sensitive
components.
CAUTION
Φ 90mm
(3-9/16")
Φ 65mm
(2-1/2")
The size of the wall hole is determined by the connective pipes. When the pipe size of the gas side
is 16mm(5/8") or more, the wall hole should be 90mm(3-9/16"). When the pipe size of gas side
is less than 16mm(5/8"), the wall hole should be 65mm(2-1/2").
NOTE
: The wall hole size
Using a 65mm (2-1/2") or 90mm(3-9/16")
core drill(depending on models )
Wall
Indoor
Outdoor
5-7mm
(3/16-5/16")
Fig.3.2
Drill the wall hole
Place the protective wall cu in the hole.
wall hole.
the protective
wall cu
Φ
Φ
199mm(7.8in)
603mm(23.7in)
322mm(12.7in)
129mm(5.1in)
55mm
(2.2in)
54mm
(2.1in)
54mm
(2.1in)
173mm
(6.8in)
W
H
172mm (6.8in)
H
W
52mm (2.05in)
389mm (15.3in)
332mm (13.05in)
257mm (10.1in)
643.6mm (25.3in)
52mm
(2.05in)
Indoor unit dimensions(WxH):
1082mm(42.6in)x337mm(13.3in)
Indoor unit dimensions(WxH):
1259mm(49.55in)x362mm(14.25in)
Φ90mm (3.54in)
Φ90mm (3.54in)
If the wall is made of brick, concrete, or similar
material, drill 5mm-diameter (0.2in-diameter)
holes in the wall and insert the sleeve anchors
provided. Then secure the mounting plate to
the wall by tightening the screws directly into
the clip anchors.
NOTE:
FOR CONCRETE OR BRICK WALLS
Using a 65mm (2.5") or 90mm(3.54")
core drill(depending on models ), drill a
hole in the wall. Make sure that the hole
is drilled at a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to
7mm (3/16-5/16"). This will ensure
proper water drainage.
Place the protective wall cu in the hole.
This protects the edges of the hole and
will help seal it when you finish the
installation process.
Step 1