Service manual
40
12. Model and Parameters
Model MSE-
07CR
MSE-
07HR
MSE-
09CR
MSE-
09HR
MSE-
12CR
MSE-
12HR
MSE-
18CR
MSE-
18HR
I
3SEC
8.5A 8.5A 10.0A 10.0A
12.0A 12.0A 16.0A 16.0A
I
5MIN
6.5A 6.5A 7.5A 7.5A
8.5A 8.5A 13.0A 13.0A
I
FAN
5.5A 5.5A 5.5A 5.5A
7.5A 7.5A 11.0A 11.0A
I
RESTORE
4.5A 4.5A 4.5A 4.5A
6.5A 6.5A 9.5A 9.5A
I
DEFROST
3.5A 3.5A
5.0A 7.5A
TE1
28
28
34
34
TE2
32
32
37
36
TE3
30
30
33
30
TE4
26
26
22
20
TE5
4
4
4
4
4
4
3
3
TE6
10
10
10
10
10
10
14
14
TE7
60
60
63
60
TE8
53
53
53
52
TE9
50
50
52
50
ANGLCOOL 88° 88° 88° 88°
88° 88° 88° 88°
ANGLHEAT 125° 125°
125° 125°
ANGLOFF 0 0 0 0
0 0 0 0
THDEFROST
15
1
7
18
1
7
TMDEFROST
16
1
8
19
1
8
TLDEFROST
17
1
9
20
1
9

Table of Contents