Service manual
41
13. Troubleshooting
13.1 Display board
This indicator illuminates when the air conditioner is in AUTO operation.
AUTO indicator
DEFROST indicator (For Cooling & Heating models only)
This indicator illuminates when the air conditioner starts defrosting automatically or
when the warm air control feature is activated in heating operation.
1 22 3
4
5
1
22
3
4
Displays the temperature settings when the air conditioner is operational.
This indicator flashes after power is on and illuminates when the unit is in operation.
This indicator illuminates when TIMER is set ON/OFF.
OPERATION indicator
TIMER indicator
TEMPERATURE indicator
5
Signal receptor
13.2 Troubleshooting
For cooling mode:
Failure phenomenon
Operation
Indoor fan speed has been out of control for over 1 minute
Indoor room temp. or evaporator sensor is open circuit or short circuit
Over current protection of the compressor occurs 4 times
For heat pump mode:
Failure phenomenon
Operation
Over current protection of the compressor occurs 4 times
Indoor fan speed has been out of control for over 1 minute
Temp. sensor on indoor evaporator is open circuit or short circuit
Indoor room temp. sensor is open circuit or short circuit