DM16-01.01.23en Kids Star Inverter
Service manual 31
10.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected Au, 20,
40,60,80 or F.
When the setting temp. is reached, if the compressor stop running, indoor fan motor will run at setting
speed.
The auto fan acts as below rules:
T1-Ts
10.4.2.4 Condenser temperature protection
T3
Resume
Off
Decrease
Hold
Increase
When condenser temperature temp. is more than setting value, the compressor will stop.
10.4.2.5 Evaporator temperature protection
When Evaporator temperature temp.is less than setting value, the compressor will stop.
10.4.3 Heating Mode
10.4.3.1 Compressor running rules
When T1-Ts>-T, the compressor will stop,
when T1-T
S
<T-1.5the compressor will be on.
T is the programmed parameter of temperature compensation.
When the AC run in mute mode, the compressor will run with low frequency.